Supply unit

Supply unit – climate control system used in various types of premises. The main purpose of this equipment is to ensure a constant supply of air and its subsequent uniform distribution. Modern Menergy units are capable of not only supplying and distributing air, but also regulating the temperature, quality and humidity of the incoming air.

screenshot 28 1

The Server-Service company implements Menergy air handling units on the territory Ташкента и Узбекистана серий MBFPW, MBFPL, MBFPD. Each series includes more than 12 models, differing in power ratings, dimensions and other technical parameters (See Table)

Product Features:

1

Duration of work The service life of the Menergy air handling unit can reach more than several decades.

2

High corrosion resistance is ensured by the use of hydrophilic aluminum foil.

3

Low noise level

4

Highly efficient motor

5

Symmetrical design will greatly simplify the installation procedure

6

Depending on cooling/heating requirements, there is Possibility of installing 4, 6 and 8-pipe models as an option.

The table of technical parameters presented below is intended to significantly facilitate the selection of a particular model. However, if certain difficulties with the choice arise, contact the managers of the Server-Service company and receive a full consultation on the issues of interest. Also, the company’s website provides the ability to fill out Questionnaires for the selection of equipment.

 Technical parameters

Technical parameters–MBFPW серия

МодельCondenser coilAir flowStatic pressureCooling capacityHeating powerFan powerWater consumptionWater resistanceNoise levelWeight
m3/hPakWkWkWm3/hkPadB (A)kg
MBFPW1.54ROWS15001357.914.70.3751.41.75390
6ROWS951117.51.94.1100
MBFPW24ROWS200012010.719.60.3751.93.25695
6ROWS8014252.47.1105
MBFPW2.54ROWS250018013.824.50.452.25.857115
6ROWS1401832.83.114.8135
MBFPW34ROWS300019016.529.40.552.88.858120
6ROWS15021383.619.4140
MBFPW44ROWS400012022390.375×23.7815.661160
6ROWS8028504.834.3180
MBFPW54ROWS500017527.5450.45×24.625.362185
6ROWS1353554657210
MBFPW64ROWS600023033610.55×25.740.163210
6ROWS19042767.233.6245
MBFPW74ROWS700024038702.213.312.965260
6ROWS20049878.415.1295
MBFPW84ROWS8000290448037.639.165315
6ROWS25056999.627.3360
MBFPW94ROWS900030050902.28.511.866320
6ROWS260631091114.9370
MBFPW104ROWS10000310559839.521.467360
6ROWS2607011812.146.5410
MBFPW124ROWS1200033066122411.42568410
6ROWS2708419214.553.9470
MBFPW154ROWS1500032085155414.63070460
6ROWS27011218919.225.3520
MBFPW204ROWS200003501101962×2.518.933.572530
6ROWS30014026224.131610
MBFPW254ROWS250004001382517.523.852.374610
6ROWS34017532030.142.3690
MBFPW304ROWS300004501653012×5.528.428.776720
6ROWS39021038036.257.8810
MBFPW354ROWS350004501923612×7533.125.578840
6ROWS39024943942.753.8980

Attention:

  1. Air circulation mode:
    Cooling: dry/wet bulb air temperature 27℃(80.6℉)/19.5℃(67.1℉); inlet/outlet water temperature 7℃(44.6℉)/12℃(53.6℉).
    Heating: dry bulb air temperature 15℃(59℉); inlet water temperature 60℃(140℉), water flow rate similar to cooling
  2. Fresh air mode:
    Cooling: dry bulb/wet bulb air temperature 35℃(95℉)/28℃(82.4℉); inlet/outlet water temperature 7℃(44.6℉)/12℃(53.6℉).
    Heating: dry bulb air temperature 7℃(44.6℉); inlet water temperature 60℃(140℉), water flow rate similar to cooling
  3. We can supply customers with equipment with non-standard requirements for static pressure upon request.
  4. Menergy reserves the exclusive right to update parameters, please refer to the table

Technical parameters–MBFPL серия

МодельCondenser coilAir flowStatic pressureCooling capacityHeating powerFan powerWater consumptionWater resistanceNoise levelWeight
m3/hPakWkWkWm3/hkPadB (A)kg
MBFPL24ROWS200019010.719.60.3751.93.25693
6ROWS13014252.47.1100
MBFPL34ROWS300024016.529.40.552.88.858150
6ROWS18021383.619.4168
MBFPL44ROWS400033022390.375×23.7815.661192
6ROWS27028504.834.3200
MBFPL54ROWS500034027.5450.45×24.625.367224
6ROWS2803554657240
MBFPL64ROWS600028033610.55×25.740.165250
6ROWS22042767.233.6260
MBFPL84ROWS8000430448037.639.167300
6ROWS37056999.627.3338
MBFPL104ROWS10000490559839.521.468419
6ROWS4307011812.146.5430
MBFPL124ROWS1200048066122411.42570445
6ROWS4208419214.553.9460
MBFPL154ROWS1500052085155414.63072503
6ROWS46011218919.225.3520
MBFPL204ROWS200004901101967.518.933.575680
6ROWS43014026224.131700
MBFPL254ROWS250006901382511123.852.376860
6ROWS63017532030.142.3880
MBFPL304ROWS300007001653011528.427.4771170
6ROWS64021038036.257.81200
MBFPL354ROWS35000680193352153351781215
6ROWS62025444942.245.51250

Technical parameters–MBFPD series

MODELCondenser coilAir flowStatic pressureCooling capacityHeating powerFan powerWater consumptionWater resistanceNoise levelWeight
m3/hPakWkWkWm3/hkPadB (A)Kg
MBFPD1.54ROWS15001008.415.20.321.495387
6ROWS6011.218.51.919.596
MBFPD24ROWS200012011.119.60.3751.9115795
6ROWS8014.5242.522.3105
MBFPD34ROWS300016016.9300.552.91858120
6ROWS12022373.828.2140
MBFPD44ROWS40001202239.20.375×23.82259160
6ROWS8028494.834.3180
MBFPD54ROWS500018027.650.80.45×24.72662185
6ROWS14035.163.46.136.5210
MBFPD64ROWS600023033.160.30.55×25.73263210
6ROWS19042.473.27.337.6245
MBFPD74ROWS700024038.470.12.26.612.965260
6ROWS20049.487.58.515.1295
MBFPD84ROWS80002804480.52.27.524.965315
6ROWS24056.21009.752.1360
MBFPD94ROWS900030051.290.838.811.866320
6ROWS2606310910.814.9370
MBFPD104ROWS100003005510139.425.267360
6ROWS2607111812.250.9410
MBFPD124ROWS1200032066121411.318.868410
6ROWS2708414614.439.9470
MBFPD154ROWS1500032085155414.63070460
6ROWS27011218919.225.3520

Attention:

  1. Air circulation mode:
    Cooling: dry/wet bulb air temperature 27℃(80.6℉)/19.5℃(67.1℉); inlet/outlet water temperature 7℃(44.6℉)/12℃(53.6℉).
    Heating: dry bulb air temperature 15℃(59℉); inlet water temperature 60℃(140℉), water flow rate similar to cooling
  2. Fresh air mode:
    Cooling: dry bulb/wet bulb air temperature 35℃(95℉)/28℃(82.4℉); inlet/outlet water temperature 7℃(44.6℉)/12℃(53.6℉).
    Heating: dry bulb air temperature 7℃(44.6℉); inlet water temperature 60℃(140℉), water flow rate similar to cooling
  3. We can supply customers with equipment with non-standard requirements for static pressure upon request.
  4. Menergy reserves the exclusive right to update parameters, please refer to the table

Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!

Contact us today to get advice and learn more about our services!

Contacts:

Telephone: +998 (71) 502 01 32, 

                     +998 (98) 128 42 00;

Email: manager.serverservice@gmail.com

We will be happy to answer your questions!

Server-Service – New level service!