Air handling unit is a climatic installation, which is used in the premises of different purpose. The main purpose of this equipment is fresh air supply and its further equal distribution. Modern Menergy units are able not only to supply but also regulate temperature, quality and humidity of input air.

Server Service Company provides the sale of Menergy air handling units of MBFPW, MBFPL, MBFPD series on the whole territory of Uzbekistan. Each series includes more than 12 models. They differ by efficiency indicators, dimensions and other technical characteristics.

Equipment properties:

  • The service life of air handling unit of Menergy installation is more than 10 years.
  • High indicators of corrosion resistance are provided with the use of hydrophilic aluminum foil.
  • Low noise level.
  • High efficient motor
  • Symmetric design significantly simplifies the process of installation.
  • Depending on requirements of heating/cooling modes, it is possible to install 4, 6 or 8 pipe models as option.

Due to represented below the table of technical parameters, you will be able to select the equipment you need. If you have any difficulties with the choice, please contact Server Service Company and our specialists will give you all necessary information. You can also to fill in the questionnaire for equipment selection.

 

Technical parameters–MBFPW series

Model Condenser coil pipe Air consumption Static pressure Cooling capacity Heating capacity Fan capacity Water consumption Water resistance Noise level Weight
m3/h Pa kW kW kW m3/h kPa dB (A) kg
MBFPW1.5 4ROWS 1500 135 7.9 14.7 0.375 1.4 1.7 53 90
6ROWS 95 11 17.5 1.9 4.1 100
MBFPW2 4ROWS 2000 120 10.7 19.6 0.375 1.9 3.2 56 95
6ROWS 80 14 25 2.4 7.1 105
MBFPW2.5 4ROWS 2500 180 13.8 24.5 0.45 2.2 5.8 57 115
6ROWS 140 18 32.8 3.1 14.8 135
MBFPW3 4ROWS 3000 190 16.5 29.4 0.55 2.8 8.8 58 120
6ROWS 150 21 38 3.6 19.4 140
MBFPW4 4ROWS 4000 120 22 39 0.375×2 3.78 15.6 61 160
6ROWS 80 28 50 4.8 34.3 180
MBFPW5 4ROWS 5000 175 27.5 45 0.45×2 4.6 25.3 62 185
6ROWS 135 35 54 6 57 210
MBFPW6 4ROWS 6000 230 33 61 0.55×2 5.7 40.1 63 210
6ROWS 190 42 76 7.2 33.6 245
MBFPW7 4ROWS 7000 240 38 70 2.2 13.3 12.9 65 260
6ROWS 200 49 87 8.4 15.1 295
MBFPW8 4ROWS 8000 290 44 80 3 7.6 39.1 65 315
6ROWS 250 56 99 9.6 27.3 360
MBFPW9 4ROWS 9000 300 50 90 2.2 8.5 11.8 66 320
6ROWS 260 63 109 11 14.9 370
MBFPW10 4ROWS 10000 310 55 98 3 9.5 21.4 67 360
6ROWS 260 70 118 12.1 46.5 410
MBFPW12 4ROWS 12000 330 66 122 4 11.4 25 68 410
6ROWS 270 84 192 14.5 53.9 470
MBFPW15 4ROWS 15000 320 85 155 4 14.6 30 70 460
6ROWS 270 112 189 19.2 25.3 520
MBFPW20 4ROWS 20000 350 110 196 2×2.5 18.9 33.5 72 530
6ROWS 300 140 262 24.1 31 610
MBFPW25 4ROWS 25000 400 138 251 7.5 23.8 52.3 74 610
6ROWS 340 175 320 30.1 42.3 690
MBFPW30 4ROWS 30000 450 165 301 2×5.5 28.4 28.7 76 720
6ROWS 390 210 380 36.2 57.8 810
MBFPW35 4ROWS 35000 450 192 361 2×75 33.1 25.5 78 840
6ROWS 390 249 439 42.7 53.8 980

Attention:

  • Air circulation mode:

Cooling: air temperature on dry/wet thermometer 27℃(80.6℉)/19.5℃(67.1℉); water temperature inlet/outlet 7℃(44.6℉)/12℃(53.6℉).

Heating: air temperature on a dry thermometer 15℃(59℉); water temperature inlet 60℃(140℉), water and cooling consumption are the same.

  • Fresh air mode:

Cooling: air temperature on dry/wet thermometer 35℃(95℉)/28℃(82.4℉); water temperature inlet/outlet 7℃(44.6℉)/12℃(53.6℉).

Heating: air temperature on a dry thermometer 7℃(44.6℉); water temperature inlet 60℃(140℉), water and cooling consumption are the same.

  • We can also install the equipment in accordance with non-standard requirements to static pressure by request.
  • Menergy Company reserves the right to update the technical parameters, please refer to the table.

 

  • Technical parameters–MBFPL series
Model Condenser coil pipe Air consumption Static pressure Cooling capacity Heating capacity Fan capacity Water consumption Water resistance Noise level Weight
m3/h Pa kW kW kW m3/h kPa dB (A) kg
MBFPL2 4ROWS 2000 190 10.7 19.6 0.375 1.9 3.2 56 93
6ROWS 130 14 25 2.4 7.1 100
MBFPL3 4ROWS 3000 240 16.5 29.4 0.55 2.8 8.8 58 150
6ROWS 180 21 38 3.6 19.4 168
MBFPL4 4ROWS 4000 330 22 39 0.375×2 3.78 15.6 61 192
6ROWS 270 28 50 4.8 34.3 200
MBFPL5 4ROWS 5000 340 27.5 45 0.45×2 4.6 25.3 67 224
6ROWS 280 35 54 6 57 240
MBFPL6 4ROWS 6000 280 33 61 0.55×2 5.7 40.1 65 250
6ROWS 220 42 76 7.2 33.6 260
MBFPL8 4ROWS 8000 430 44 80 3 7.6 39.1 67 300
6ROWS 370 56 99 9.6 27.3 338
MBFPL10 4ROWS 10000 490 55 98 3 9.5 21.4 68 419
6ROWS 430 70 118 12.1 46.5 430
MBFPL12 4ROWS 12000 480 66 122 4 11.4 25 70 445
6ROWS 420 84 192 14.5 53.9 460
MBFPL15 4ROWS 15000 520 85 155 4 14.6 30 72 503
6ROWS 460 112 189 19.2 25.3 520
MBFPL20 4ROWS 20000 490 110 196 7.5 18.9 33.5 75 680
6ROWS 430 140 262 24.1 31 700
MBFPL25 4ROWS 25000 690 138 251 11 23.8 52.3 76 860
6ROWS 630 175 320 30.1 42.3 880
MBFPL30 4ROWS 30000 700 165 301 15 28.4 27.4 77 1170
6ROWS 640 210 380 36.2 57.8 1200
MBFPL35 4ROWS 35000 680 193 352 15 33 51 78 1215
6ROWS 620 254 449 42.2 45.5 1250

 

Technical parameters–MBFPD series

Model Condenser coil pipe Air consumption Static pressure Cooling capacity Heating capacity Fan capacity Water consumption Water resistance Noise level Weight
m3/h Pa kW kW kW m3/h kPa dB (A) kg
MBFPD1.5 4ROWS 1500 100 8.4 15.2 0.32 1.4 9 53 87
6ROWS 60 11.2 18.5 1.9 19.5 96
MBFPD2 4ROWS 2000 120 11.1 19.6 0.375 1.9 11 57 95
6ROWS 80 14.5 24 2.5 22.3 105
MBFPD3 4ROWS 3000 160 16.9 30 0.55 2.9 18 58 120
6ROWS 120 22 37 3.8 28.2 140
MBFPD4 4ROWS 4000 120 22 39.2 0.375×2 3.8 22 59 160
6ROWS 80 28 49 4.8 34.3 180
MBFPD5 4ROWS 5000 180 27.6 50.8 0.45×2 4.7 26 62 185
6ROWS 140 35.1 63.4 6.1 36.5 210
MBFPD6 4ROWS 6000 230 33.1 60.3 0.55×2 5.7 32 63 210
6ROWS 190 42.4 73.2 7.3 37.6 245
MBFPD7 4ROWS 7000 240 38.4 70.1 2.2 6.6 12.9 65 260
6ROWS 200 49.4 87.5 8.5 15.1 295
MBFPD8 4ROWS 8000 280 44 80.5 2.2 7.5 24.9 65 315
6ROWS 240 56.2 100 9.7 52.1 360
MBFPD9 4ROWS 9000 300 51.2 90.8 3 8.8 11.8 66 320
6ROWS 260 63 109 10.8 14.9 370
MBFPD10 4ROWS 10000 300 55 101 3 9.4 25.2 67 360
6ROWS 260 71 118 12.2 50.9 410
MBFPD12 4ROWS 12000 320 66 121 4 11.3 18.8 68 410
6ROWS 270 84 146 14.4 39.9 470
MBFPD15 4ROWS 15000 320 85 155 4 14.6 30 70 460
6ROWS 270 112 189 19.2 25.3 520

Attention:

  • Air circulation mode:

Cooling: air temperature on dry/wet thermometer 27℃(80.6℉)/19.5℃(67.1℉); water temperature inlet/outlet 7℃(44.6℉)/12℃(53.6℉).

Heating: air temperature on a dry thermometer 15℃(59℉); water temperature inlet 60℃(140℉), water and cooling consumption are the same.

  • Fresh air mode:

Cooling: air temperature on dry/wet thermometer 35℃(95℉)/28℃(82.4℉); water temperature inlet/outlet 7℃(44.6℉)/12℃(53.6℉).

Heating: air temperature on a dry thermometer 7℃(44.6℉); water temperature inlet 60℃(140℉), water and cooling consumption are the same.

  • We can also install the equipment in accordance with non-standard requirements to static pressure by request.
  • Menergy Company reserves the right to update the technical parameters, please refer to the table.