Ducted fan coils (hidden type)
Fan coils today represent an important element of air conditioning in most modern buildings. Fan coils replaced the air conditioners and took their places tightly. Speaking of distinctive features, it is worth noting that fan coils do not require the installation of outdoor units on the walls of buildings, like air conditioners. Fan coils work in conjunction with air conditioners. Fan coils are widely used in apartments, shops, offices and hospitals.
Fan coils Canada Menergy they are a complex device consisting of a fan, a heat exchanger, a housing and electrical elements. The ventilator rotation has several speed phases, and synchronous operation together with an air condenser allows you to consume a minimum of electricity.
Product features:
1
The possibility of choosing a two-pipe or three-pipe model.
2
The pleasant appearance of the product will perfectly fit any necessary conditions.
3
The motor and fan work in tandem and provide the best performance, low noise and stable operation.
4
The material of manufacture is a sheet of galvanized steel.
5
The symmetry of the design is adapted to any conditions. The pipe connection can be carried out both on the left and on the right.
6
The use of hydrophilic aluminum foil significantly improves the resistance to corrosion and other types of chemical destruction of the metal.
The range of ducted fan coils from Canada Menergy includes more than 25 types. In order to understand which of the fan coils is most suitable for you, it is recommended to fill out the “Questionnaire for the selection of equipment“, or contact the specialists of the Server–Service company at one of the numbers indicated in the section “Contacts”.
Technical parameters
Fan Coil (Hidden type)Two pipes
| Model | MFP 34-2 | MFP 51-2 | MFP 68-2 | MFP 85-2 | MFP 102-2 | MFP 136-2 | MFP 170-2 | MFP 204-2 | MFP 238-2 | |
| Cooling capacity | W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
| Heating capacity | 3400 | 4100 | 5400 | 6800 | 8100 | 10800 | 13500 | 16200 | 18900 | |
| Electrical parameters(V/Ph/Hz) | 230/1/50 | |||||||||
| Air consumption (m3/h) | High | 400 | 550 | 780 | 900 | 1060 | 1500 | 1800 | 2140 | 2500 |
| Medium | 330 | 450 | 590 | 680 | 800 | 1100 | 1350 | 1560 | 1960 | |
| Low | 260 | 290 | 400 | 450 | 560 | 740 | 900 | 1100 | 1250 | |
| Power consumption | Standard | 37 | 52 | 62 | 75 | 96 | 134 | 152 | 189 | 228 |
| 30 Pa static press | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | |
| 50 Pa static press | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | |
| Water consumption(kg/h) | 330 | 465 | 620 | 755 | 930 | 1239 | 1548 | 1857 | 2160 | |
| Water resistance | 5 | 8 | 16 | 23 | 32 | 10 | 20 | 30 | ||
| Ventilator& motor | Type | Centrifugal | ||||||||
| Ventilator | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | |
| Мotor | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | |
| Noise level (dB/A) | Standard | ≤35 | ≤36 | ≤39 | ≤42 | ≤45 | ≤44 | ≤46 | ≤49 | ≤50 |
| 30 Pa static press | ≤39 | ≤40 | ≤43 | ≤44 | ≤47 | ≤48 | ≤49 | ≤51 | ≤52 | |
| 50 Pa static press | ≤41 | ≤43 | ≤44 | ≤46 | ≤49 | ≤50 | ≤51 | ≤53 | ≤54 | |
| Overall dimensions | Length (mm) | 750 | 850 | 920 | 1050 | 1250 | 1650 | 1850 | 1950 | 2050 |
| Width (mm) | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | |
| Height (mm) | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | |
| Package Dimensions | Length (mm) | 772 | 872 | 972 | 1072 | 1276 | 1676 | 1876 | 1976 | 2076 |
| Width (mm) | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | |
| Height (mm) | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | |
| The coil | Copper pipes with double-sided ribs(1.8mm); Operating pressure 1.6MPa | |||||||||
| Inlet/outlet pipe | RC3/4″(DN20) | RC3/4″(DN20) | RC3/4″(DN20) | |||||||
| Weight(Kg) | 12 | 14 | 15 | 17 | 18 | 26 | 30 | 32 | 36 | |
Attention:
- Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); water temperature 7℃(44.6℉).
- Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); water temperature 60℃(140℉).
- Menergy reserves the unique right to update the parameters, please refer to the sign.
| Model | MFP 34-3 | MFP 51-3 | MFP 68-3 | MFP 85-3 | MFP 102-3 | MFP 136-3 | MFP 170-3 | MFP 204-3 | MFP 238-3 | |
| Cooling capacity | W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
| Heating capacity | 3400 | 4100 | 5400 | 6800 | 8100 | 10800 | 13500 | 16200 | 18900 | |
| Electrical parameters(V/Ph/Hz) | 230/1/50 | |||||||||
| Air consumption (m3/h) | High | 400 | 550 | 680 | 900 | 1060 | 1500 | 1800 | 2140 | 2500 |
| Ventilator | 330 | 450 | 590 | 680 | 800 | 1100 | 1350 | 1560 | 1960 | |
| Low | 260 | 290 | 400 | 450 | 560 | 740 | 900 | 1100 | 1250 | |
| Power consumption | Standard | 37 | 52 | 62 | 75 | 96 | 134 | 152 | 189 | 228 |
| 30 Pa static press | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | |
| 50 Pa static press | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | |
| Water consumption(kg/h) | 330 | 465 | 620 | 755 | 930 | 1239 | 1548 | 1857 | 2160 | |
| Water resistance | 5 | 8 | 16 | 23 | 32 | 10 | 20 | 30 | ||
| Ventilator& Motor | Type | Centrifugal | ||||||||
| Ventilator | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | |
| Motor | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | |
| Noise level(dB/A) | Standard | ≤35 | ≤36 | ≤39 | ≤42 | ≤45 | ≤44 | ≤46 | ≤49 | ≤50 |
| 30 Pa static press | ≤39 | ≤40 | ≤43 | ≤44 | ≤47 | ≤48 | ≤49 | ≤51 | ≤52 | |
| 50 Pa static press | ≤41 | ≤43 | ≤44 | ≤46 | ≤49 | ≤50 | ≤51 | ≤53 | ≤54 | |
| Overall dimensions | Length (mm) | 750 | 850 | 920 | 1050 | 1250 | 1650 | 1850 | 1950 | 2050 |
| Width (mm) | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | |
| Height (mm) | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | |
| Package Dimensions | Length (mm) | 772 | 872 | 972 | 1072 | 1276 | 1676 | 1876 | 1976 | 2076 |
| Width (mm) | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | |
| Height (mm) | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | |
| The coil | Copper pipes with double-sided ribs (1.8mm); Operating pressure 1.6MPa | |||||||||
| Inlet/outlet pipe | RC3/4″(DN20) | RC3/4″(DN20) | RC3/4″(DN20) | |||||||
| Weight(Kg) | 12 | 14 | 15 | 17 | 18 | 26 | 30 | 32 | 36 | |
Attention:
- Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); water temperature 7℃(44.6℉).
- Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); water temperature 60℃(140℉).
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Four pipes (three for cooling and one for heating)
| Model | MFP 34-3+1 | MFP 51-3+1 | MFP 68-3+1 | MFP 85-3+1 | MFP 102-3+1 | MFP 136-3+1 | MFP 170-3+1 | MFP 204-3+1 | MFP 238-3+1 | |
| Cooling capacity | W | 1970 | 2860 | 3700 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
| Heating capacity | 1810 | 2390 | 3270 | 3830 | 4690 | 6240 | 6920 | 8110 | 9450 | |
| Electrical parameters(V/Ph/Hz) | 230/1/50 | |||||||||
| Air consumption (m3/h) | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Ventilator | 270 | 380 | 510 | 640 | 780 | 1020 | 1290 | 1530 | 1870 | |
| Motor | 190 | 290 | 340 | 450 | 530 | 750 | 890 | 1040 | 1230 | |
| Power consumption | Standard | 42 | 55 | 65 | 82 | 102 | 146 | 168 | 190 | 250 |
| 30 Pa static press | 47 | 62 | 75 | 95 | 110 | 165 | 190 | 230 | 280 | |
| 50 Pa static press | 340 | 490 | 645 | 790 | 935 | 1250 | 1550 | 1857 | 2230 | |
| Water consumption (kg/h) | 201 | 269 | 372 | 440 | 538 | 734 | 824 | 977 | 1152 | |
| Water resistance | 8 | 17 | 27 | 20 | 28 | 30 | 38 | 40 | 46 | |
| Ventilator& Motor | Type | 12 | 20 | 31 | 33 | 33 | 35 | 41 | 44 | 48 |
| Ventilator | Centrifugal | |||||||||
| Motors | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | |
| Noise level(dB/A) | Standard | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
| 30 Pa static press | ≤35 | ≤36 | ≤39 | ≤42 | ≤45 | ≤44 | ≤46 | ≤49 | ≤50 | |
| 50 Pa static press | ≤39 | ≤40 | ≤43 | ≤44 | ≤47 | ≤48 | ≤49 | ≤51 | ≤52 | |
| Overall dimensions | Length (mm) | 750 | 850 | 920 | 1050 | 1250 | 1650 | 1850 | 1950 | 2050 |
| Width (mm) | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | 465 | |
| Height (mm) | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | |
| Package Dimensions | Length (mm) | 772 | 872 | 972 | 1072 | 1276 | 1676 | 1876 | 1976 | 2076 |
| Width (mm) | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | 480 | |
| Height (mm) | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | |
| The coil | Copper pipes with double-sided ribs(1.8mm); operating pressure 1.6MPa | |||||||||
| Inlet/outlet pipe | RC3/4″(DN20) | RC3/4″(DN20) | RC3/4″(DN20) | |||||||
| Weight(Kg) | 17 | 19 | 23 | 25 | 27 | 34 | 42 | 48 | 54 | |
Attention:
- Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); the difference between the inlet/outlet water temperature 5℃(41℉).
- Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); inlet water temperature 60℃(140℉).
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Server-Service – your reliable partner in Uzbekistan!
Our services:
1
High quality: We use only high-quality materials and equipment from the world’s leading manufacturers.
2
Professionalism: Our specialists have extensive experience and high qualifications.
3
Individual approach: We develop individual solutions for each client, taking into account their requirements and the specifics of the facility.
4
Affordable prices: We offer competitive prices for our services.
Server-Service – your reliable partner in the field of HVAC!
Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!
Contact us today to get advice and learn more about our services!
Contacts:
Telephone: +998 (70) 202 01 32, +998 (98) 128 42 00;
Telephone: +998 (70) 202 01 32,
Email: manager.serverservice@gmail.com
We will be happy to answer your questions!
Server-Service – New level service!