Ducted fan coils (hidden type)

Fan coils today represent an important element of air conditioning in most modern buildings. Fan coils replaced the air conditioners and took their places tightly. Speaking of distinctive features, it is worth noting that fan coils do not require the installation of outdoor units on the walls of buildings, like air conditioners. Fan coils work in conjunction with air conditioners. Fan coils are widely used in apartments, shops, offices and hospitals.

fankoil tica tcrq1200c min 1

Fan coils Canada Menergy they are a complex device consisting of a fan, a heat exchanger, a housing and electrical elements. The ventilator rotation has several speed phases, and synchronous operation together with an air condenser allows you to consume a minimum of electricity.

Product features:

1

The possibility of choosing a two-pipe or three-pipe model.

2

The pleasant appearance of the product will perfectly fit any necessary conditions.

3

The motor and fan work in tandem and provide the best performance, low noise and stable operation.

4

The material of manufacture is a sheet of galvanized steel.

5

The symmetry of the design is adapted to any conditions. The pipe connection can be carried out both on the left and on the right.

6

The use of hydrophilic aluminum foil significantly improves the resistance to corrosion and other types of chemical destruction of the metal.

The range of ducted fan coils from Canada Menergy includes more than 25 types. In order to understand which of the fan coils is most suitable for you, it is recommended to fill out the  Questionnaire for the selection of equipment, or contact the specialists of the ServerService company at one of the numbers indicated in the section Contacts.

Technical parameters

Fan Coil (Hidden type)Two pipes

ModelMFP
34-2
MFP
51-2
MFP
68-2
MFP
85-2
MFP
102-2
MFP
136-2
MFP
170-2
MFP
204-2
MFP
238-2
Cooling capacityW18002700360045005400720090001080012600
Heating capacity3400410054006800810010800135001620018900
Electrical parameters(V/Ph/Hz)230/1/50
Air consumption
(m3/h)
High40055078090010601500180021402500
Medium3304505906808001100135015601960
Low26029040045056074090011001250
Power consumptionStandard3752627596134152189228
30 Pa static press44597287108156174212253
50 Pa static press496684100118174210250300
Water consumption(kg/h)3304656207559301239154818572160
Water resistance58162332102030 
Ventilator& motorTypeCentrifugal 
Ventilator122223444
Мotor111112222
Noise level (dB/A)Standard≤35≤36≤39≤42≤45≤44≤46≤49≤50
30 Pa static press≤39≤40≤43≤44≤47≤48≤49≤51≤52
50 Pa static press≤41≤43≤44≤46≤49≤50≤51≤53≤54
Overall dimensionsLength (mm)750850920105012501650185019502050
Width (mm)465465465465465465465465465
Height (mm)240240240240240240240240240
Package DimensionsLength (mm)772872972107212761676187619762076
Width (mm)480480480480480480480480480
Height (mm)260260260260260260260260260
The coilCopper pipes with double-sided ribs(1.8mm); Operating pressure 1.6MPa
Inlet/outlet pipeRC3/4″(DN20)RC3/4″(DN20)RC3/4″(DN20)
Weight(Kg)121415171826303236

Attention:

  1. Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); water temperature 7℃(44.6℉).
  2. Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); water temperature 60℃(140℉).
  3. Menergy reserves the unique right to update the parameters, please refer to the sign.

Three pipes

ModelMFP
34-3
MFP
51-3
MFP
68-3
MFP
85-3
MFP
102-3
MFP
136-3
MFP
170-3
MFP
204-3
MFP
238-3
Cooling capacityW18002700360045005400720090001080012600
Heating capacity3400410054006800810010800135001620018900
Electrical parameters(V/Ph/Hz)230/1/50
Air consumption
(m3/h)
High40055068090010601500180021402500
Ventilator3304505906808001100135015601960
Low26029040045056074090011001250
Power consumptionStandard3752627596134152189228
30 Pa static press44597287108156174212253
50 Pa static press496684100118174210250300
Water consumption(kg/h)3304656207559301239154818572160
Water resistance58162332102030 
Ventilator& MotorTypeCentrifugal 
Ventilator122223444
Motor111112222
Noise level(dB/A)Standard≤35≤36≤39≤42≤45≤44≤46≤49≤50
30 Pa static press≤39≤40≤43≤44≤47≤48≤49≤51≤52
50 Pa static press≤41≤43≤44≤46≤49≤50≤51≤53≤54
Overall dimensionsLength (mm)750850920105012501650185019502050
Width (mm)465465465465465465465465465
Height  (mm)240240240240240240240240240
Package DimensionsLength (mm)772872972107212761676187619762076
Width (mm)480480480480480480480480480
Height (mm)260260260260260260260260260
The coilCopper pipes with double-sided ribs (1.8mm); Operating pressure 1.6MPa
Inlet/outlet pipeRC3/4″(DN20)RC3/4″(DN20)RC3/4″(DN20)
Weight(Kg)121415171826303236

Attention:

  1. Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); water temperature 7℃(44.6℉).
  2. Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); water temperature 60℃(140℉).
  3. Menergy reserves the unique right to update the parameters, please refer to the sign.

Four pipes (three for cooling and one for heating)

ModelMFP
34-3+1
MFP
51-3+1
MFP
68-3+1
MFP
85-3+1
MFP
102-3+1
MFP
136-3+1
MFP
170-3+1
MFP
204-3+1
MFP
238-3+1
Cooling capacityW19702860370045005400720090001080012600
Heating capacity181023903270383046906240692081109450
Electrical parameters(V/Ph/Hz)230/1/50
Air consumption
(m3/h)
High34051068085010201360170020402380
Ventilator2703805106407801020129015301870
Motor19029034045053075089010401230
Power consumptionStandard42556582102146168190250
30 Pa static press47627595110165190230280
50 Pa static press3404906457909351250155018572230
Water consumption (kg/h)2012693724405387348249771152
Water resistance81727202830384046
Ventilator& MotorType122031333335414448
VentilatorCentrifugal 
Motors122223444
Noise level(dB/A)Standard111112222
30 Pa static press≤35≤36≤39≤42≤45≤44≤46≤49≤50
50 Pa static press≤39≤40≤43≤44≤47≤48≤49≤51≤52
Overall dimensionsLength (mm)750850920105012501650185019502050
Width (mm)465465465465465465465465465
Height (mm)240240240240240240240240240
Package DimensionsLength (mm)772872972107212761676187619762076
Width (mm)480480480480480480480480480
Height (mm)260260260260260260260260260
The coilCopper pipes with double-sided ribs(1.8mm); operating pressure 1.6MPa
Inlet/outlet pipeRC3/4″(DN20)RC3/4″(DN20)RC3/4″(DN20)
Weight(Kg)171923252734424854

Attention:

  1. Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉); the difference between the inlet/outlet water temperature 5℃(41℉).
  2. Heating mode: the air temperature inside the room according to a dry thermometer 21℃(69.8℉); inlet water temperature 60℃(140℉).
  3. Menergy reserves the unique right to update the parameters, please refer to the sign.

Server-Service – your reliable partner in Uzbekistan!

Our services:

1

High quality: We use only high-quality materials and equipment from the world’s leading manufacturers.

2

Professionalism: Our specialists have extensive experience and high qualifications.

3

Individual approach: We develop individual solutions for each client, taking into account their requirements and the specifics of the facility.

4

Affordable prices: We offer competitive prices for our services.

Server-Service – your reliable partner in the field of HVAC!

Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!

Contact us today to get advice and learn more about our services!

Contacts:

Telephone: +998 (70) 202 01 32, 

                     +998 (98) 128 42 00;

Email: manager.serverservice@gmail.com

We will be happy to answer your questions!

Server-Service – New level service!