NAVIEN LST floor-standing liquid fuel boilers
Compactness The boilers have small dimensions.measures with excellent characteristics, the use of stainless steel allows to extend the life of the boiler for a very long time, while improving its thermal characteristics and efficiency.
Simplicity and convenience
The boiler design is simple, but ensures efficient operation and easy control. The control panel can be used to set operating modes by timer, by water temperature in the heating system or by air temperature in the room. The “absence” function allows you to save fuel, while preventing the heating system from freezing.
Safety:
Combustion control unit
Automatically stops the boiler if for some reason combustion does not occur, fuel (gas, liquid fuel) is not supplied)
Power Failure Protection Unit
If the power supply in the network disappears, the boiler automatically stops working; when the power supply is restored, the boiler also automatically returns to working condition.
Overheating protection unit
If there is no water in the heating system, or if the control panel breaks down during boiler operation, the temperature increases sharply. In this case, overheating protection is triggered, protecting the boiler from destruction
Freeze protection
During the cold season, the boiler automatically turns on the circulation pump and burner to prevent the heating system from freezing.
Fan protection block
If the fan breaks down, the pressure in the chimney surges, or the chimney becomes clogged, the boiler automatically stops working.
Low water level protection
When the water level in the boiler drops below the permissible level, the boiler stops working.
Heat exchanger material:
GTD Series – Stainless Steel
GPD Series – Refractory Steel
Technical information – Navien series GTD
Model |
535 GTD | 735 GTD | ||
Heating area | m2 | 580 | 810 | |
Thermal power of heating | kW | 58,1 | 81,3 | |
Hot water pressure | bar | Max. – 9,8 | ||
Hot water performance | dT=25°C | l/min | 33 | 46 |
dT=40°C | l/min | 21 | 29 | |
Maximum heating temperature | °С | 80 | ||
Maximum pressure in the system | kg/cm2 | 3,5 | ||
Gas pressure | mBar | 15-27 | ||
Maximum gas consumption | m3/h | 5,8 | 8 | |
КПД | % | 89 | 88,6 | |
Power supply | V/Hz | 220/50 | ||
Pipe diameter | вх/вых heating | mm | 40 | |
Input/output ГВС | mm | 20 | ||
Gas inlet | mm | 15 | ||
Chimney | mm | 148 | ||
Dimensions | Ш*Г*В | 547*850*1032 | 547*838*1240 | |
Weight | kg | 160 | 193 |
Technical information – Navien series GPD
Model |
1035 GPD | 1535 GPD | 2035 GPD | ||
Heating area | m2 | 1160 | 1740 | 2320 | |
Thermal power of heating | kW | 116 | 174.4 | 232.6 | |
Hot water pressure | bar | Max. – 9.8 | |||
Hot water performance | dT=25°C | l/min | 63 | 81 | 130 |
dT=40°C | l/min | 42 | 54 | 87.8 | |
Maximum heating temperature | °С | 80 | |||
Maximum pressure in the system | kg/cm2 | 3.5 | |||
Gas pressure | mBar | 10-27 | |||
Maximum gas consumption | m3/h (kg/h) | 11.8 | 17 | 24 | |
КПД | % | 81.3 | 85.5 | 84.6 | |
Power supply | V/Hz | 220/50 | |||
Pipe diameter | вх/вых Heating | mm | 65 | 80 | |
Input/output ГВС | mm | 20 | |||
Gas inlet | mm | 20 | 25 | 32 | |
Chimney | mm | 200 | |||
Dimensions | Ш*Г*В | 769*1073*1411 | 796*1073*1464 | 796*1165*1588 | |
Weight | kg | 290 | 390 | 470 |
Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!
Contact us today to get advice and learn more about our services!
Contacts:
Telephone: +998 (70) 202 01 32, +998 (98) 128 42 00;
Telephone: +998 (70) 202 01 32,
Email: manager.serverservice@gmail.com
We will be happy to answer your questions!