Greenhouses equipping with reliable and uninterruptible heating system is the most important element in the field of farm enterprise. Fruits and vegetables grown in greenhouses are in a great demand among our people. Winter food products for farmers are the special form of income.
The main factor of greenhouses operation is maintenance of desirable temperature. Microclimate depends on such important aspects as type of plants, season, heated area and much more. From the finance point of view, the energy saving is also one of the most important problems. In accordance with mentioned above requirements, special heat pumps were produced by Menergy Company.
Features of heat pumps for greenhouses:
- Low operating costs of heat pump.
- The equipment can be used all year round.
- Absence of such harmful substances as dust, carbon dioxide which adversely affect the plants.
- Long service life depends on production process and professional assemblage. Packed heat pumps have a reliable protection from overloading, voltage jump and other parameters.
“Server Service” Company provides the services of installation of heat pumps Menergy on the whole territory of Uzbekistan. For more information, please contact our specialists by one of the telephone numbers: +998 (71) 207-33-32
Technical characteristics
Model MSMZRW-60L | Refrigerant circuit | Water circuit | |
Nominal cooling capacity | kW | 45 | 45 |
Nominal heating capacity | kW | 50 | 63 |
Air consumption (Regulated) | m³/h | Air supply 2000~6000; Return air:0~6000; New fresh air:0~6000 |
|
Internal pressure | Pa | 200 | |
Power consumption in cooling mode | kW | 11.5 | 2.45 |
Power consumption in heating mode | kW | 12.5 | 2.45 |
Current consumption in cooling mode | A | 19.6 | 4.5 |
Current consumption in heating mode | A | 22 | 4.5 |
Noise level | dB(A) | 58 | |
Dimension (L×W×H) | mm | 1800x1000x1660 | |
Weight | kg | 680 | |
Water consumption | m³/h | 6.3 (Cooling) 2.76(Heating) | |
Refrigerant/volume | kg | R22/2.1×4 | |
Chilled water pipe diameter | in | R1 -1/2 | |
Hot water pipe diameter | in | R1 -1/2 | |
Condensate pipe diameter | in | R1 |
Attention:
- Refrigerant circuit in cooling mode: fresh air temperature on dry/ wet thermometer 27℃/19℃, water temperature at inlet/outlet 30℃/35℃
- Refrigerant circuit in heating mode: fresh air temperature on dry/wet thermometer 20℃/15℃, water temperature at inlet 10℃, air consumption 4,76 m3/h
- Water circuit in cooling mode: fresh air temperature on dry/wet thermometer 35/28 ℃, water temperature at inlet/outlet 15℃/35℃
- Water circuit in heating mode: fresh air temperature on dry/wet thermometer 20℃/15℃, water temperature at inlet 60℃, water consumption 2.76m³/h
- Menergy Company reserves the right to update the parameters
Model MSMZRW-60L | Refrigerant circuit | Water circuit | |
Nominal cooling capacity | kW | 60 | 60 |
Nominal heating capacity | kW | 58. 8 | 102 |
Air consumption (Regulated) | m³/h | Air supply: 3000~10000; Return air: 0~6000; New fresh air: 0~10000 |
|
Internal pressure | Pa | 200 | |
Power consumption in cooling mode | kW | 14. 7 | 3.75 |
Power consumption in heating mode | kW | 12.5 | 3.75 |
Current consumption in cooling mode | A | 23. 2 | 5.8 |
Current consumption in heating mode | A | 22. 7 | 5.8 |
Noise level | dB(A) | 68 | |
Dimension (L×W×H) | mm | 2400×1190×2460 | |
Weight | kg | 710 | |
Water consumption | m³/h | 11. 4(Cooling) 4 .76(Heating) | |
Refrigerant/volume | kg | 3.5×4 | |
Chilled water pipe diameter | in | R2-1/2 | |
Hot water pipe diameter | in | R2-1/2 | |
Condensate pipe diameter | in | R1-1/4 |
Attention:
- Refrigerant circuit in cooling mode: fresh air temperature on dry/ wet thermometer 27℃/19℃, water temperature at inlet/outlet 30℃/35℃
- Refrigerant circuit in heating mode: fresh air temperature on dry/wet thermometer 20℃/15℃, water temperature at inlet 10℃, air consumption 4,76 m3/h
- Water circuit in cooling mode: fresh air temperature on dry/wet thermometer 35/28 ℃, water temperature at inlet/outlet 15℃/35℃
- Water circuit in heating mode: fresh air temperature on dry/wet thermometer 20℃/15℃, water temperature at inlet 60℃, water consumption 2.76m³/h
- Menergy Company reserves the right to update the parameters