Heat pump water-air split system
The use of split systems with a heat pump is one of the main innovative solutions in the field of air conditioning and heating systems in recent years. Menergy saving is also one of the positive aspects in using split systems with a water-air class heat pump. The scope of use of these installations is not limited and includes residential buildings, shops, cafes, restaurants, office premises and much more.

Features of Menergy’s split systems:
1
Due to the presence of a coaxial tubular heat exchanger of large diameter, heat transfer efficiency, reliability of operation and high frost resistance are guaranteed.
2
The refrigerants used are R-410A, R-407C, and R-22 as an option.
3
Silent operation is ensured thanks to unique anti-vibration technologies (Patent ZL 2020 2,024,3049.7) and the use of modern sound-absorbing materials.
4
An intelligent microcomputer is responsible for managing the system. A simple and automatic man-machine control interface on a large LCD display.
5
The temperature at the outlet and inlet, the temperature of the equipment, the exhaust temperature of the compressor can be adjusted depending on the necessary conditions.
6
The possibility of centralized management and ON/OFF Internet booking is provided thanks to unique patent developments (Patent ZL 2010 2,0243047.8)
It is important to know! In order to avoid additional financial costs, it is necessary to determine how much power the installation will require. All the technical parameters will be listed below, based on which it will be possible to make the right choice. However, if you have any questions, please contact the Server-Service company to get qualified help by numbers
(+998 71) 207-33-32
Technical parameters:
Water Loop
Model | Internal | 2600FY | 3500FY | 4500FY | 5800FY | 7200FY | 8600FY | 10500FY | 12600FY | 14600FY | |
Outdoor | 2600W | 3500W | 4500W | 5800W | 7200W | 8600W | 10500W /S | 12600W /S | 14600W | ||
Cooling capacity(KW) | 2.6 | 3.5 | 4.5 | 5.8 | 7.2 | 8.6 | 10.5 | 12.6 | 14.6 | ||
EER | 4.64 | 4.27 | 4.41 | 4.30 | 4.37 | 4.43 | 4.12 | 4.17 | 4.21 | ||
Heating capacity(KW) | 3.00 | 3.95 | 5.10 | 6.48 | 8.10 | 9.40 | 11.40 | 13.60 | 15.80 | ||
COP | 4.76 | 4.65 | 4.64 | 4.47 | 4.66 | 4.63 | 4.21 | 4.20 | 4.27 | ||
Air consumption (m3/h) | 500 | 700 | 910 | 1190 | 1480 | 1760 | 2150 | 2570 | 3010 | ||
External static pressure(Pa) | 12(8) | 20(12) | 30(20) | 50(30) | |||||||
Incoming cooling power(KW) | 0.59 | 0.82 | 1.02 | 1.35 | 1.65 | 1.94 | 2.51 | 3.02 | 3.47 | ||
Incoming heating power(KW) | 0.63 | 0.85 | 1.10 | 1.45 | 1.74 | 2.03 | 2.71 | 3.24 | 3.70 | ||
Electrical parameters (V/Ph/Hz) | 230/1/50 | 380~420/3/50 | |||||||||
Incoming cooling current(A) | 2.7 | 3.9 | 4.9 | 6.5 | 7.8 | 9.3 | 3.9 | 4.7 | 5.4 | ||
Incoming current in the heating(A) | 3.0 | 4.0 | 5.2 | 6.9 | 8.2 | 9.7 | 4.2 | 5.0 | 5.7 | ||
Type/Compressor quantity | Rotary/1 | Spiral/1 | |||||||||
Noise level dB(A) | Internal | 35 | 35 | 37 | 37 | 40 | 41 | 42 | 42 | 42 | |
Outdoor | 30 | 31 | 32 | 32 | 35 | 36 | 36 | 38 | 38 | ||
Overall dimensions (LxWxH) | Internal | 855*475 *235 | 1005*475 *235 | 1125*475 *235 | 1355*475 *235 | 1605*475 *235 | 1750*475 *235 | 2005*475 *235 | 2065*490*285 | ||
Outdoor | 550*430*385 | 590*430 *385 | 550*490 *420 | 635*520*510 | 695*520 *535 | 720*580*535 | |||||
Weight (kg) | Internal | 18 | 22 | 26 | 30 | 34 | 36 | 40 | 50 | 55 | |
Outdoor | 34 | 35 | 40 | 48 | 66 | 68 | 90 | 90 | 100 | ||
Water consumption (m3/h) | 0.58 | 0.72 | 0.92 | 1.25 | 1.52 | 1.85 | 2.25 | 2.66 | 3.12 | ||
Water pressure drop(Pa) | 18 | 22 | 30 | 35 | 35 | 35 | 35 | 38 | 38 | ||
Connecting pipe | Liquids(mm) | Ø6×0.75 | Ø9.52×0.75 | Ø12.7×0.75 | |||||||
Gas(mm) | Ø9.52×0.75 | Ø12.7×0.75 | Ø16×1.0 | Ø19×1.0 | |||||||
Cooling water pipe(diameter) | R3/4(DN20) | R1(DN25) | R1-1/4(DN32) | ||||||||
Condensate pipe(diameter) | R3/4(DN20) | ||||||||||
Volume(kg) | 0.65 | 0.84 | 0.95 | 1.1 | 1.5 | 1.8 | 2.1 | 2.3 | 2.8 |
Attention:
- In cooling mode: air temperature according to dry/wet thermometer is 27℃/19℃ ; water temperature is 30℃/35℃ (input/output).
- In heating mode: air temperature 20℃/15℃(according to dry/wet thermometer) ; water temperature 20℃ at the inlet.
- Equipment with the cooling function only does not have parameters in the heating mode.
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Ground Water
Model | Internal | 2600FY | 3500FY | 4500FY | 5800FY | 7200FY | 8600FY | 10500FY | 12600FY | 14600FY | |
Outdoor | 2600W | 3500W | 4500W | 5800W | 7200W | 8600W | 10500W /S | 12600W /S | 14600W | ||
Cooling capacity(KW) | 2.6 | 3.5 | 4.5 | 5.8 | 7.2 | 8.6 | 10.5 | 12.6 | 14.6 | ||
EER | 4.73 | 4.43 | 4.09 | 4.46 | 4.44 | 4.57 | 4.36 | 4.41 | 4.79 | ||
Heating capacity(KW) | 2.80 | 3.70 | 4.50 | 5.70 | 7.30 | 8.70 | 10.40 | 12.50 | 14.50 | ||
COP | 4.59 | 4.51 | 4.09 | 4.29 | 4.17 | 4.46 | 4.05 | 4.15 | 4.53 | ||
Cooling capacity(USRT) | 0.74 | 1.00 | 1.29 | 1.66 | 2.06 | 2.46 | 3.00 | 3.60 | 4.17 | ||
Heating capacity(USRT) | 0.80 | 1.06 | 1.29 | 1.63 | 2.09 | 2.49 | 2.97 | 3.49 | 4.14 | ||
Air consumption (m3/h) | 520 | 715 | 910 | 1190 | 1480 | 1760 | 2150 | 2570 | 3010 | ||
External static pressure(Pa) | 12(8) | 20(12) | 30(20) | 50(30) | |||||||
Incoming cooling power(KW) | 0.55 | 0.79 | 1.1 | 1.3 | 1.62 | 1.88 | 2.41 | 2.86 | 3.05 | ||
Incoming heating power(KW) | 0.61 | 0.82 | 1.10 | 1.33 | 1.75 | 1.95 | 2.57 | 3.01 | 3.20 | ||
Electrical parameters (V/Ph/Hz) | 230/1/50 | 380~420/3/50 | |||||||||
Incoming cooling current(A) | 2.7 | 3.8 | 5.1 | 6.3 | 7.8 | 8.6 | 4.6 | 5.5 | 5.8 | ||
Incoming current in the heating(A) | 2.9 | 3.9 | 5.1 | 6.4 | 8.4 | 8.4 | 4.9 | 5.8 | 6.2 | ||
Type/compressor quantity | Rotary/1 | Spiral/1 | |||||||||
Noise level dB(A) | Internal | 35 | 35 | 37 | 40 | 48 | 48 | 52 | 54 | 55 | |
Outdoor | 30 | 31 | 32 | 35 | 46 | 40 | 48 | 51 | 52 | ||
Overall dimensions (LxWxH) | Internal | 855*475 *235 | 1005*475 *235 | 1125*475 *235 | 1355*475 *235 | 1605*475 *235 | 1750*475 *235 | 2005*475 *235 | 2065*490*285 | ||
Outdoor | 550*430*385 | 550*430*420 | 635*520*510 | 695*520 *535 | 720*580*535 | ||||||
Weight (kg) | Internal | 18 | 22 | 28 | 30 | 34 | 36 | 40 | 50 | 55 | |
Outdoor | 34 | 35 | 40 | 46 | 66 | 75 | 90 | 90 | 100 | ||
Water consumption(m3/h) | 0.27 | 0.38 | 0.5 | 0.61 | 0.78 | 0.96 | 1.07 | 1.31 | 1.5 | ||
Water pressure drop(Pa) | 8.4 | 10.6 | 11 | 11.6 | 10.8 | 13.5 | 30.2 | 42 | 45 | ||
Connecting pipe | Liquids(mm) | Ø6×0.75 | Ø9.52×0.75 | Ø12.7×0.75 | |||||||
Gas(mm) | Ø9.52×0.75 | Ø12.7×0.75 | Ø16×1.0 | Ø19×1.0 | |||||||
Cooling water pipe(diameter) | R3/4(DN20) | R1(DN25) | R1-1/4(DN32) | ||||||||
Condensate pipe(diameter) | R3/4(DN20) | ||||||||||
Volume(kg) | 0.65 | 0.84 | 0.95 | 1.1 | 1.5 | 1.7 | 2.0 | 2.3 | 2.5 |
Attention:
- In cooling mode: air temperature according to dry/wet thermometer is 27℃/19℃ ; water temperature is 30℃/35℃ (input/output).
- In heating mode: air temperature 20℃/15℃(according to dry/wet thermometer) ; water temperature 15℃ at the inlet.
- Equipment with the cooling function only does not have parameters in the heating mode.
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Underground Loop
Model | Internal | 2600FY | 3500FY | 4500FY | 5800FY | 7200FY | 8600FY | 10500FY | 12600FY | 14600FY | |
Outdoor | 2600W | 3500W | 4500W | 5800W | 7200W | 8600W | 10500W /S | 12600W /S | 14600W /S | ||
Cooling capacity(KW) | 2.6 | 3.5 | 4.5 | 5.8 | 7.2 | 8.6 | 10.5 | 12.6 | 14.6 | ||
EER | 4.33 | 4.49 | 4.25 | 4.20 | 4.19 | 4.28 | 4.27 | 4.16 | 4.35 | ||
Heating capacity(KW) | 2.48 | 3.20 | 4.10 | 5.30 | 6.60 | 7.90 | 9.60 | 11.50 | 13.10 | ||
COP | 4.28 | 4.21 | 4.06 | 4.21 | 4.15 | 4.34 | 3.95 | 4.05 | 4.34 | ||
Cooling capacity(USRT) | 0.74 | 1.00 | 1.29 | 1.66 | 2.06 | 2.46 | 3.00 | 3.60 | 4.17 | ||
Heating capacity(USRT) | 0.71 | 0.91 | 1.17 | 1.46 | 1.86 | 2.23 | 2.68 | 3.08 | 3.57 | ||
Air consumption (m3/h) | 520 | 715 | 910 | 1190 | 1480 | 1760 | 2150 | 2570 | 3010 | ||
External static pressure(Pa) | 12(8) | 20(12) | 30(20) | 50(30) | |||||||
Incoming cooling power(KW) | 0.6 | 0.78 | 1.06 | 1.38 | 1.72 | 2.01 | 2.46 | 3.03 | 3.36 | ||
Incoming heating power(KW) | 0.58 | 0.76 | 1.01 | 1.26 | 1.59 | 1.82 | 2.43 | 2.84 | 3.02 | ||
Electrical parameters (V/Ph/Hz) | 230/1/50 | 380~420/3/50 | |||||||||
Incoming cooling current(A) | 2.9 | 3.7 | 5.1 | 6.6 | 8.2 | 9.2 | 4.7 | 5.8 | 6.5 | ||
Incoming current in the heating(A) | 2.8 | 3.6 | 4.8 | 6.0 | 7.6 | 8.3 | 4.7 | 5.5 | 5.8 | ||
Type/compressor quantity | Rotary/1 | Spiral/1 | |||||||||
Noise level dB(A) | Internal | 35 | 35 | 37 | 37 | 40 | 48 | 52 | 54 | 55 | |
Outdoor | 30 | 31 | 32 | 35 | 46 | 40 | 48 | 51 | 52 | ||
Overall dimensions (LxWxH) | Internal | 855*475 *235 | 1005*475 *235 | 1125*475 *235 | 1355*475 *235 | 1605*475 *235 | 1750*475 *235 | 2005*475 *235 | 2065*490*285 | ||
Outdoor | 550*430*385 | 550*430*420 | 635*520*510 | 695*520 *535 | 720*580*535 | ||||||
Weight (kg) | Internal | 18 | 22 | 28 | 30 | 34 | 36 | 40 | 50 | 55 | |
Outdoor | 34 | 35 | 40 | 46 | 66 | 75 | 90 | 90 | 100 | ||
Water consumption(m3/h) | 0.59 | 0.8 | 0.95 | 1.29 | 1.61 | 1.95 | 2.28 | 2.83 | 3.25 | ||
Water pressure drop(Pa) | 11.2 | 12.6 | 13.6 | 13.2 | 14.4 | 22 | 33.9 | 45.2 | 47 | ||
Connecting pipe | Liquids(mm) | Ø6×0.75 | Ø9.52×0.75 | Ø12.7×0.75 | |||||||
Gas(mm) | Ø9.52×0.75 | Ø12.7×0.75 | Ø16×1.0 | Ø19×1.0 | |||||||
Cooling water pipe(diameter) | R3/4(DN20) | R1(DN25) | R1-1/4(DN32) | ||||||||
Condensate pipe(diameter) | R3/4(DN20) | ||||||||||
Volume(kg) | 0.6 | 0.7 | 0.95 | 1 | 1.3 | 1.7 | 2 | 2.3 | 2.5 |
Attention:
- In cooling mode: air temperature 27℃/19℃(according to dry/wet thermometer); water temperature 25℃ /30℃ (input/output).
- In heating mode: air temperature 20℃/15℃(according to dry/wet thermometer) ; water temperature 10℃ at the inlet.
- Equipment with the cooling function only does not have parameters in the heating mode.
- Energy reserves the unique right to update the parameters, please refer to the sign.
Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!
Contact us today to get advice and learn more about our services!
Contacts:
Telephone: +998 (70) 202 01 32, +998 (98) 128 42 00;
Telephone: +998 (70) 202 01 32,
Email: manager.serverservice@gmail.com
We will be happy to answer your questions!
Server-Service – New level service!