Heat Pump Water-Water

A distinctive feature of horizontal heat pumps is their shape and installation method. The dimensions of horizontal heat pumps range from 960×615 ×730 to 1500×1000×1450 depending on the power of the unit.

4 3

Product features:

1

Due to the fact that the coaxial heat exchanger has a large diameter, the device guarantees high heat transfer efficiency. Also, the reliability of operation and high frost resistance.

2

The technology of gradual wear reduces the electrical impulse, thereby increasing the durability of this installation.

3

Modular technology.

4

A microcomputer is installed in the equipment, which performs control. The control interface on the large LCD display allows you to use the system without much difficulty.

5

In addition to the control on the device itself, there is also the possibility of remote control via the Internet or phone.

6

Silent operation is ensured by unique anti-vibration developments for compressors (Patent ZL 2020 2,024,3049.7) and the use of modern noise-absorbing materials.

7

Refrigerating agents R410a, R407C, R134a, R22

8

The device has a heat recovery function.

9

The developed method of control of the mobile unit (patent ZL 2020 2,024,3049.7) Facilitates the installation, detection, operation and maintenance of horizontal TN.

Below is a detailed technical description of each model of these units. Based on the parameters below, you can make a choice in favor of one or another model, based on certain conditions. However.

Technical parameters

Parameters (Water Loop)

ModelMSSH(R)-
7500
MSSH(R)-
10000
MSSH(R)-
12000
MSSH(R)-
15000/S
MSSH(R)-
20000/S
MSSH(R)-
25000/S
Cooling capacity(KW)7.99.811.714.518.523.6
EER4.164.364.434.434.834.47
Cooling capacity(USRT)2.152.93.54.155.67.15
Heating capacity(KW)8.9121517.52128
COP4.244.754.954.714.724.95
Heating capacity(USRT)2.553.54.356.68.3
Incoming cooling power(KW)1.92.252.643.273.835.28
Incoming heating power(KW)2.12.83.214.144.876.42
Electrical parameters (V/Ph/Hz)230/1/50380~420/3/50
Incoming cooling current(A)8.64.456.16.910
Incoming current in the heating(A)9.55.367.38.512
Compressor TypeRotarySpiral
Type of refrigerantR410A
Overall dimensions( L*W*H) (mm)960×615 ×730930×600× 8401000×600× 9001050×655× 8101100×705× 8501150×700× 770
Side of the heat sourceWater resistance(kPa)282831343845
Pipe dimensionsR1(DN25)R1-1/4(DN25)
Water consumption (m3h)1.62.22.63.24.25.4
Side of useWater resistance(kPa)262729333333
Pipe dimensionsR1(DN25)R1-1/4(DN25)
Water consumption(m3h)1.31.72.12.63.44.3
Noise leveldB(A)505254565858
Weight (kg)85100105120150250
Power WireYZW 3×2.5YZW 3×4YZW 4×4+1×1.5

Attention:

  1. Cooling mode: the temperature of the cooling water at the inlet/outlet is 12℃/7℃; the water temperature at the inlet/outlet of the water loop is 30℃/35℃
  2. Heating mode: the temperature of the heated water at the inlet/outlet is 40°/45°; the water temperature at the inlet/outlet of the water loop is 15°/9°
  3. Menergy reserves the unique right to update the parameters, please refer to the sign

Parameters (Water Loop)

ModelMSSH(R)-
30000/S
MSSH(R)-
40000/S
MSSH(R)-
50000/S
MSSH(R)-
60000/S
MSSH(R)-
80000/S
Cooling capacity(KW)29.237.149.354.273.2
EER4.464.714.404.614.62
Cooling capacity(USRT)912151723
Heating capacity(KW)394667.472.197.3
COP4.714.725.345.225.02
Heating capacity(USRT)1013161824
Incoming cooling power(KW)6.547.8811.211.7615.86
Incoming heating power(KW)8.289.7412.6113.819.4
Electrical parameters (V/Ph/Hz)380~420/3/50
Incoming cooling current(A)12.913.819.820.727.6
Incoming current in the heating(A)14.617.122.624.433.8
Compressor TypeSpiral
Type of refrigerantR410A
Overall dimensions( L*W*H) (mm)1150×700×7701150×700×9601450×874×13021600×874×1321500×1000×1450
Side of the heat sourceWater resistance(kPa)6570858590
Pipe dimensionsR1-1/2(DN40)R2(DN50)R2-1/2(DN65)
Water consumption (m3h)6.28.610.712.216.8
Side of useWater resistance(kPa)3435454555
Pipe dimensionsR1-1/2(DN40)
Water consumption (m3h)4.96.88.69.813.4
Noise level dB(A)5862636567
Weight (kg)280300420450700
Power wireYZW 4×4+1×1.5YZW 4×6+1×4YZW 4×10+1×6

Attention:

  1. Cooling mode: the temperature of the cooling water at the inlet/outlet is 12℃/7℃; the water temperature at the inlet/outlet of the water loop is 30℃/35℃
  2. Heating mode: the temperature of the heated water at the inlet/outlet is 40℃(/45℃; the water temperature at the inlet/outlet of the water loop is 15℃/9℃
  3. Menergy reserves the unique right to update the parameters, please refer to the sign

Parameters (Geothermal Loop)

ModelMSSM(R)-
7500
MSSM(R)-
10000
MSSM(R)-
12000
MSSM(R)-
15000/S
MSSM(R)-
20000/S
MSSM(R)-
25000/S
Cooling capacity(KW)8.110.112.414.819.524.8
EER5.235.085.285.075.565.28
Cooling capacity(USRT)2.233.554.35.87.4
Нeating capacity(KW)8.210.312.615.520.425.3
COP4.103.683.773.664.113.83
Нeating capacity(USRT)2.233.664.265.67.06
Incoming cooling power(KW)1.551.992.352.923.514.7
Incoming heating power(KW)22.83.344.234.966.6
Electrical parameters (V/Ph/Hz)230/1/50380~420/3/50
Incoming cooling current(A)7.24.14.45.66.38.3
Incoming current in the heating(A)9.25.36.37.58.712.6
Compressor typeRotarySpiral
Type of refrigerantR410A
Overall dimensions( L*W*H) (mm)960×615× 730930×600× 8401000×600× 9001050×655× 8101100×705× 8501150×700× 770
Side of the heat sourceWater resistance(kPa)282831343845
Pipe dimensionsR1(DN25)R1-1/4(DN25)
Water consumption (m3h)1.62.12.63.14.25.3
Side of useWater resistancekPa)262729333333
Pipe dimensionsR1(DN25)R1-1/4(DN25)
Water consumption (m3h)1.31.82.12.63.54.4
Noise leveldB(A)505254565858
Weight (kg)85100105120150250
Power wireYZW 3×2.5YZW 3×4YZW 4×4+1×1.5

Attention:

  1. Cooling mode: the temperature of the cooling water at the inlet/outlet is 12℃/7℃; the water temperature at the inlet/outlet of the water loop is 30℃/35℃
  2. Heating mode: heated water inlet/outlet temperature 40℃/45℃; water temperature at the inlet/outlet of the water loop 10℃/9℃
  3. Menergy reserves the unique right to update the parameters, please refer to the sign

Parameters (Geothermal loop)

ModelMSSM(R)-
30000/S
MSSM(R)-
40000/S
MSSM(R)-
50000/S
MSSM(R)-
60000/S
MSSM(R)-
80000/S
Cooling capacity(KW)29.53950.756.376.3
EER5.055.565.235.315.16
Cooling capacity(USRT)8.412151723
Heating capacity(KW)31.240.853.258.778.6
COP3.694.113.773.944.03
Heating capacity(USRT)8.51113.615.320.4
Incoming cooling power(KW)5.847.029.710.614.8
Incoming heating power(KW)8.459.0214.114.919.5
Electrical parameters (V/Ph/Hz)380~420/3/50
Incoming cooling current(A)11.212.517.618.925.8
Incoming current in the heating(A)14.917.324.925.635.4
Compressor typeSpiral
Type of refrigerantR410A
Overall dimensions( L*W*H) (mm)1150×700×7701150×700×9601450×874×13021600×874×1321500×1000×1450
Side of the heat sourceWater resistance(kPa)6570858590
Pipe dimensionsR1-1/2(DN40)R2(DN50)R2-1/2(DN65)
Water consumption (m3h)6.38.710.912.517.2
Use sideWater resistance(kPa)3435454555
Pipe dimensionsR1-1/2(DN40)R2(DN50)R2-1/2(DN65)
Расход воды (m3h)5.178.910.113.9
Noise level dB(A)5862636567
Weight (kg)280300420450700
Power wireYZW 4×4+1×1.5YZW 4×6+1×4YZW 4×10+1×6

Attention:

  1. Cooling mode: the temperature of the cooling water at the inlet/outlet is 12℃/7℃; the water temperature at the inlet/outlet of the water loop is 30℃/35℃
  2. Heating mode: heated water inlet/outlet temperature 40℃/45℃; water temperature at the inlet/outlet of the water loop 10℃/9℃
  3. Menergy reserves the unique right to update the parameters, please refer to the sign

Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!

Contact us today to get advice and learn more about our services!

Contacts:

Telephone: +998 (71) 502 01 32, 

                     +998 (98) 128 42 00;

Email: manager.serverservice@gmail.com

We will be happy to answer your questions!

Server-Service – New level service!