Heat pump Water-Water
The main advantage of horizontal heat pumps is its shape and way of installation. Sizes of horizontal heat pumps is from 960x615x730 to 1500x1000x1450 depending on equipment capacity.
Features of the equipment:
- Due to big size of coaxial heat exchanger, a high efficiency of heat exchange, reliable operation and high indicators of freezing resistance are guaranteed.
- Technology of gradual wear reduces electric pulse, thereby improving the life ratio of the equipment.
- Module technology.
- The equipment has a microcomputer which is responsible for its control. There is a control interface on LCD display with the help of which one can use with the system without any difficulties.
- It is also possible to control remotely. For example, using the telephone or internet.
- Noiseless operation is provided with unique anti-vibration developments for compressors (Licence ZL 2020 2 0243049.7) and use of modern acoustic absorber materials.
- Refrigerants R410a, R407C, R134a, R22.
- The equipment has the function of heat recuperation.
- Developed method of mobile unit control (licence ZL 2020 2 0243049.7) makes easy the installation, operation and maintenance of horizontal heat pump.
There are technical parameters of each model in the table below. According to these parameters, you will be able to choose the equipment you need. If you have any question, please call “Server Service” Company by telephone number +998 (71) 207 33 32 and you will get all necessary information.
Technical parameters
Water loop
Model | MSSH(R)- 7500 |
MSSH(R)- 10000 |
MSSH(R)- 12000 |
MSSH(R)- 15000/S |
MSSH(R)- 20000/S |
MSSH(R)- 25000/S |
|
Nominal cooling capacity (KW) | 7.9 | 9.8 | 11.7 | 14.5 | 18.5 | 23.6 | |
EER | 4.16 | 4.36 | 4.43 | 4.43 | 4.83 | 4.47 | |
Cooling capacity (USRT) | 2.15 | 2.9 | 3.5 | 4.15 | 5.6 | 7.15 | |
Nominal heating capacity (KW) | 8.9 | 12 | 15 | 17.5 | 21 | 28 | |
COP | 4.24 | 4.75 | 4.95 | 4.71 | 4.72 | 4.95 | |
Heating capacity (USRT) | 2.55 | 3.5 | 4.3 | 5 | 6.6 | 8.3 | |
Input power in cooling (KW) | 1.9 | 2.25 | 2.64 | 3.27 | 3.83 | 5.28 | |
Input power in heating (KW) | 2.1 | 2.8 | 3.21 | 4.14 | 4.87 | 6.42 | |
Electric parameters (V/Ph/Hz) | 230/1/50 | 380~420/3/50 | |||||
Input current in cooling (A) | 8.6 | 4.4 | 5 | 6.1 | 6.9 | 10 | |
Input current in heating (A) | 9.5 | 5.3 | 6 | 7.3 | 8.5 | 12 | |
Type of compressor | Rotational | Spiral | |||||
Type of refrigerant | R410A | ||||||
Domension ( L*W*H) (mm) | 960×615 ×730 | 930×600× 840 | 1000×600× 900 | 1050×655× 810 | 1100×705× 850 | 1150×700× 770 | |
Heat source side | Size of pipe | 28 | 28 | 31 | 34 | 38 | 45 |
Water consumption (m3h) | R1(DN25) | R1-1/4(DN25) | |||||
Water resistance (kPa) | 1.6 | 2.2 | 2.6 | 3.2 | 4.2 | 5.4 | |
Use side | Size of pipe | 26 | 27 | 29 | 33 | 33 | 33 |
Water consumption (m3h) | R1(DN25) | R1-1/4(DN25) | |||||
Size of pipe | 1.3 | 1.7 | 2.1 | 2.6 | 3.4 | 4.3 | |
Noise level dB(A) | 50 | 52 | 54 | 56 | 58 | 58 | |
Weight (kg) | 85 | 100 | 105 | 120 | 150 | 250 | |
Power wire | YZW 3×2.5 | YZW 3×4 | YZW 4×4+1×1.5 |
Attention:
- Cooling mode: temperature of chilled water at inlet/outlet 12 ℃/7℃; water temperature at inlet/outlet of water loop is 30℃/35℃
- Heating mode: temperature of hot water at inlet/outlet 40℃/45℃; water temperature at inlet/outlet of water loop is 15℃/9℃
- Menergy Company reserves the right to update the parameters
Parameters (Water loop)
Model | MSSH(R)- 30000/S |
MSSH(R)- 40000/S |
MSSH(R)- 50000/S |
MSSH(R)- 60000/S |
MSSH(R)- 80000/S |
|
Nominal cooling capacity (KW) | 29.2 | 37.1 | 49.3 | 54.2 | 73.2 | |
EER | 4.46 | 4.71 | 4.40 | 4.61 | 4.62 | |
Cooling capacity (USRT) | 9 | 12 | 15 | 17 | 23 | |
Nominal heating capacity (KW) | 39 | 46 | 67.4 | 72.1 | 97.3 | |
COP | 4.71 | 4.72 | 5.34 | 5.22 | 5.02 | |
Heating capacity (USRT) | 10 | 13 | 16 | 18 | 24 | |
Input power in cooling (KW) | 6.54 | 7.88 | 11.2 | 11.76 | 15.86 | |
Input power in heating (KW) | 8.28 | 9.74 | 12.61 | 13.8 | 19.4 | |
Electric parameters (V/Ph/Hz) | 380~420/3/50 | |||||
Input power in cooling (A) | 12.9 | 13.8 | 19.8 | 20.7 | 27.6 | |
Input power in heating (A) | 14.6 | 17.1 | 22.6 | 24.4 | 33.8 | |
Type of compressor | Spiral | |||||
Type of refrigerant | R410A | |||||
Dimension ( L*W*H) (mm) | 1150×700×770 | 1150×700×960 | 1450×874×1302 | 1600×874×132 | 1500×1000×1450 | |
Heat source side | Water resistance (kPa) | 65 | 70 | 85 | 85 | 90 |
Size of pipe | R1-1/2(DN40) | R2(DN50) | R2-1/2(DN65) | |||
Water consumption (m3h) | 6.2 | 8.6 | 10.7 | 12.2 | 16.8 | |
Use side | Water resistance (kPa) | 34 | 35 | 45 | 45 | 55 |
Size of pipe | R1-1/2(DN40) | |||||
Water consumption (m3h) | 4.9 | 6.8 | 8.6 | 9.8 | 13.4 | |
Noise level dB(A) | 58 | 62 | 63 | 65 | 67 | |
Weight (kg) | 280 | 300 | 420 | 450 | 700 | |
Power wire | YZW 4×4+1×1.5 | YZW 4×6+1×4 | YZW 4×10+1×6 |
Attention:
- Cooling mode: temperature of chilled water at inlet/outlet 12 ℃/7℃; water temperature at inlet/outlet of water loop is 30℃/35℃
- Heating mode: temperature of hot water at inlet/outlet 40℃/45℃; water temperature at inlet/outlet of water loop is 15℃/9℃
- Menergy Company reserves the right to update the parameters
Geothermic loop
Model | MSSM(R)- 7500 |
MSSM(R)- 10000 |
MSSM(R)- 12000 |
MSSM(R)- 15000/S |
MSSM(R)- 20000/S |
MSSM(R)- 25000/S |
|
Nominal cooling capacity (KW) | 8.1 | 10.1 | 12.4 | 14.8 | 19.5 | 24.8 | |
EER | 5.23 | 5.08 | 5.28 | 5.07 | 5.56 | 5.28 | |
Cooling capacity (USRT) | 2.2 | 3 | 3.55 | 4.3 | 5.8 | 7.4 | |
Nominal heating capacity (KW) | 8.2 | 10.3 | 12.6 | 15.5 | 20.4 | 25.3 | |
COP | 4.10 | 3.68 | 3.77 | 3.66 | 4.11 | 3.83 | |
Heating capacity (USRT) | 2.2 | 3 | 3.66 | 4.26 | 5.6 | 7.06 | |
Input power in cooling (KW) | 1.55 | 1.99 | 2.35 | 2.92 | 3.51 | 4.7 | |
Input power in heating (KW) | 2 | 2.8 | 3.34 | 4.23 | 4.96 | 6.6 | |
Electric parameters (V/Ph/Hz) | 230/1/50 | 380~420/3/50 | |||||
Input power in cooling (A) | 7.2 | 4.1 | 4.4 | 5.6 | 6.3 | 8.3 | |
Input power in heating (A) | 9.2 | 5.3 | 6.3 | 7.5 | 8.7 | 12.6 | |
Type of compressor | Rotational | Spiral | |||||
Type of refrigerant | R410A | ||||||
Dimension ( L*W*H) (mm) | 960×615× 730 | 930×600× 840 | 1000×600× 900 | 1050×655× 810 | 1100×705× 850 | 1150×700× 770 | |
Heat source side | Water resistance (kPa) | 28 | 28 | 31 | 34 | 38 | 45 |
Size of pipe | R1(DN25) | R1-1/4(DN25) | |||||
Water consumption (m3h) | 1.6 | 2.1 | 2.6 | 3.1 | 4.2 | 5.3 | |
Use side | Water resistance (kPa) | 26 | 27 | 29 | 33 | 33 | 33 |
Size of pipe | R1(DN25) | R1-1/4(DN25) | |||||
Water consumption (m3h) | 1.3 | 1.8 | 2.1 | 2.6 | 3.5 | 4.4 | |
Noise level dB(A) | 52 | 54 | 56 | 58 | 58 | ||
Weight (kg) | 100 | 105 | 120 | 150 | 250 | ||
Power wire | YZW 3×4 | YZW 4×4+1×1.5 |
Attention:
- Cooling mode: temperature of chilled water at inlet/outlet 12 ℃/7℃; water temperature at inlet/outlet of water loop is 30℃/35℃
- Heating mode: temperature of hot water at inlet/outlet 40℃/45℃; water temperature at inlet/outlet of water loop is 10℃/9℃
- Menergy Company reserves the right to update the parameters
Geothermic loop
Model | MSSM(R)- 30000/S |
MSSM(R)- 40000/S |
MSSM(R)- 50000/S |
MSSM(R)- 60000/S |
MSSM(R)- 80000/S |
|
Nominal cooling capacity (KW) | 29.5 | 39 | 50.7 | 56.3 | 76.3 | |
EER | 5.05 | 5.56 | 5.23 | 5.31 | 5.16 | |
Cooling capacity (USRT) | 8.4 | 12 | 15 | 17 | 23 | |
Nominal heating capacity (KW) | 31.2 | 40.8 | 53.2 | 58.7 | 78.6 | |
COP | 3.69 | 4.11 | 3.77 | 3.94 | 4.03 | |
Heating capacity (USRT) | 8.5 | 11 | 13.6 | 15.3 | 20.4 | |
Input power in cooling (KW) | 5.84 | 7.02 | 9.7 | 10.6 | 14.8 | |
Input power in heating (KW) | 8.45 | 9.02 | 14.1 | 14.9 | 19.5 | |
Electric parameters (V/Ph/Hz) | 380~420/3/50 | |||||
Input power in cooling (A) | 11.2 | 12.5 | 17.6 | 18.9 | 25.8 | |
Input power in heating (A) | 14.9 | 17.3 | 24.9 | 25.6 | 35.4 | |
Type of compressor | Spiral | |||||
Type of refrigerant | R410A | |||||
Dimension ( L*W*H) (mm) | 1150×700×770 | 1150×700×960 | 1450×874×1302 | 1600×874×132 | 1500×1000×1450 | |
Heat source side | Water resistance (kPa) | 65 | 70 | 85 | 85 | 90 |
Size of pipe | R1-1/2(DN40) | R2(DN50) | R2-1/2(DN65) | |||
Water consumption (m3h) | 6.3 | 8.7 | 10.9 | 12.5 | 17.2 | |
Use side | Water resistance (kPa) | 34 | 35 | 45 | 45 | 55 |
Size of pipe | R1-1/2(DN40) | R2(DN50) | R2-1/2(DN65) | |||
Water consumption (m3h) | 5.1 | 7 | 8.9 | 10.1 | 13.9 | |
Noise level dB(A) | 62 | 63 | 65 | 67 | ||
Weight (kg) | 300 | 420 | 450 | 700 | ||
Power wire | YZW 4×6+1×4 | YZW 4×10+1×6 |
Attention:
- Cooling mode: temperature of chilled water at inlet/outlet 12 ℃/7℃; water temperature at inlet/outlet of water loop is 30℃/35℃
- Heating mode: temperature of hot water at inlet/outlet 40℃/45℃; water temperature at inlet/outlet of water loop is 10℃/9℃