Modular heat pump is a system of cooling and heating of premises which use ground heat for heating in cold season and elimination of heat in the warm season. These devices are widely used in the different types of buildings, from industrial enterprises to kinder gardens.

Equipment features:

  • Refrigerants R410A, R407C и R22 provide hot water supply.
  • Modular technology allows to select the equipment depending on needed loading of cooling.
  • Microcomputer with intelligent control provides simple operation of the equipment.
  • It is also possible to control remotely, using telephone or internet. However, it is necessary to install a special software on your phone or PC, connected to the network.
  • The device is equipped with the system of switching between heating and cooling modes in the water circuits/ refrigerant.
  • The device is equipped with the function of heat recuperation with a capacity more than 30%.

There is more information about technical parameters of different models of geothermic modular heat pumps Menergy in the table below. According to these parameters, one can make a right choice of the equipment you need. If you have any questions. Please call our company by one of the telephone numbers: +998 (71) 207-33-32

Technical parameters

Underground ground water

Model MSSM-60W2 MSSM-90W3 MSSM-120W4
Cooling mode Nominal cooling capacity(kW) 73 110 146
EER 5.18 5.19 5.18
Cooling capacity (USRT) 21 32 42
103kcal/h 62.9 94.3 125.8
Power consumption (kW) 14.1 21.2 28.2
Chilled water consumption (m³/h) 12.5 18.8 25.1
Water pressure drop (kPa) 42 45 50
Chilled water consumption (m³/h) 6.8 10.2 13.6
Water pressure drop (kPa) 12 15 15
Heating mode Nominal heating capacity (kW) 82 123 164
COP 4.29 4.29 4.29
Heating capacity (USRT) 24 35 47
103kcal/h 66.5 99.8 66.5
Power consumption (kW) 19.1 28.7 38.2
Chilled water consumption (m³/h) 6.8 10.2 13.6
Water pressure drop (kPa) 25 25 25
Chilled water consumption (m³/h) 12.5 18.8 25.1
Water pressure drop (kPa) 45 50 50
Electric parameters (V/Ph/Hz) 380~420/3/50
Capacity control (%) 0,50,100 0,33,66,100 0,25,50,75,100
Devices of protection High-low pressure protection , safe valve ,overload protection,
Inverse/lack phase protection, water-lack, anti-freeze protector ,coils overheat
Condenser Type Shell-and-tube
Water pipe diameter at inlet/outlet (mm) DN65 DN65 DN65
Evaporator Тype Shell-and-tube
Water pipe diameter at inlet/outlet (mm) DN65 DN65 DN65
Dimension (mm) Width 1980 2170 2680
Height 1390 1410 1410
Length 550 600 600
Netto weight (kg) 510 590 590
Noise level dB(A) 66 66 67
Refrigerant Type R410a
Volume (kg) 15.5 23 31
Throttle Thermostatic expansion valve

Attention:

  1. Cooling mode: chilled water temperature at inlet/outlet 12℃ (53.6℉)/7℃ (44.6℉); water temperature from the side of heat source at inlet/outlet 18℃ (64.4℉)/29℃ (84.2℉).
  2. Heating mode: hot water temperature at inlet/outlet 40℃ (104℉)/45℃ (113℉); water temperature from the side of heat source at inlet/outlet 15℃ (59℉)/7℃ (44.6℉).
  3. Noise level data is determined at the distance of 1 m. and a height of 1.5 m.
  4. Menergy Company reserves the right to update the parameters, please refer to the table.

 

Geothermic loop

Model MSSM-60W2 MSSM-90W3 MSSM-120W4
Cooling mode Nominal cooling capacity(kW) 73 110 146
EER 5.18 5.19 5.18
Cooling capacity (USRT) 21 32 42
103kcal/h 62.9 94.3 125.8
Power consumption (kW) 14.1 21.2 28.2
Chilled water consumption (m³/h) 12.5 18.8 25.1
Water pressure drop (kPa) 42 45 50
Chilled water consumption (m³/h) 6.8 10.2 13.6
Water pressure drop (kPa) 12 15 15
Heating mode Nominal heating capacity (kW) 82 123 164
COP 4.29 4.29 4.29
Heating capacity (USRT) 24 35 47
103kcal/h 66.5 99.8 66.5
Power consumption (kW) 19.1 28.7 38.2
Chilled water consumption (m³/h) 6.8 10.2 13.6
Water pressure drop (kPa) 25 25 25
Chilled water consumption (m³/h) 12.5 18.8 25.1
Water pressure drop (kPa) 45 50 50
Electric parameters (V/Ph/Hz) Electric parameters (V/Ph/Hz)
Capacity control (%) Capacity control (%) 0,33,66,100 0,25,50,75,100
Devices of protection Devices of protection
Condenser Condenser Shell-and-tube
DN65 DN65 DN65
Evaporator Evaporator Shell-and-tube
DN65 DN65 DN65
Dimension (mm) Dimension (mm) 1980 2170 2680
1390 1410 1410
550 600 600
Netto weight (kg) Netto weight (kg) 590 590
Noise level dB(A) Noise level dB(A) 66 67
Refrigerant Refrigerant R410a
15.5 23 31
Throttle Throttle

Attention:

  1. Cooling mode: chilled water temperature at inlet/outlet 12℃ (53.6℉)/7℃ (44.6℉); water temperature from the side of heat source at inlet/outlet 25℃ (77℉)/30℃ (86℉).
  2. Heating mode: hot water temperature at inlet/outlet 40℃ (104℉)/45℃ (113℉); water temperature from the side of heat source at inlet/outlet 10℃ (50℉)/5℃ (41℉).
  3. Noise level data is determined at the distance of 1 m. and a height of 1.5 m.
  4. Menergy Company reserves the right to update the parameters.