Packaged Heat Pump (Condenser Water Cooling Chiller)
Packaged type heat pumps (condenser water cooling chillers) they have their own distinctive features. They are used in a wide variety of buildings from hotels to hospitals. The use of such powerful and oversized heat pumps in residential conditions is impractical. However, in large industrial or public facilities, they are much more relevant.

Product features:
1
With high efficiency indicators, these Menergy units have low energy consumption.
2
The durability of the service is largely ensured by the manufacturing technology and the professionalism of the assembly. Packaged heat pumps have reliable protection against overloads, voltage fluctuations of electric current and other similar parameters adversely affecting any electrical equipment.
3
The materials from which Menergy heat pumps are made have excellent sound-absorbing qualities. Thereby ensuring the silent operation of the entire unit.
4
Performance adjustment if necessary.
5
Each element of the packaged type pumps has high efficiency indicators. Among them, a reflux condenser, a shell-and-tube heat exchanger and a copper pipe on the inside stand out.
6
The monoblock design, coupled with a compact shape, allows you to install the unit without much difficulty and get more free space.
7
An on-board microcomputer that performs intelligent control. The human control interface is displayed on a large LCD display.
8
Equipping with a single cycle circulation system will help meet the different needs of customers depending on their requirements. In addition, the single cycle circulation system greatly simplifies repair and maintenance.
In order to avoid additional financial costs, it is necessary to determine how much power a packaged type heat pump you will need. All the technical parameters will be listed below, based on which it will be possible to make the right choice.
Technical parameters
Specifications
Model | MF(D)-28 | MF(D)-32 | MF(D)-40 | MF(D)-53 | MF(D)-64 | MF(D)-72 | |
Cooling capacity(kW) | 28 | 32 | 40 | 53 | 64 | 72 | |
Cooling capacity(EER) | 4.38 | 4.21 | 4.26 | 4.27 | 4.21 | 4.40 | |
Cooling capacity (USRT) | 8 | 10 | 11.5 | 15.2 | 18.3 | 21 | |
Air consumption (m3/h) | 4800 | 5500 | 7200 | 9500 | 11500 | 12800 | |
Performance regulation | 0-50-100 | 0-25-50-75-100 | |||||
Compressor power (kW) | 3.2×2 | 3.8×2 | 4.7×2 | 3.1×4 | 3.8×4 | 4.1×4 | |
External static pressure (Pa) | 80 | 100 | 100 | 120 | 150 | 200 | |
Electrical parameters(V/Ph/Hz) | 380~420/3/50 | ||||||
Compressor | Sealed spiral compressor | ||||||
Vaporizer | Edge & Copper pipes | ||||||
Ventilator drive | Belt drive | ||||||
Condenser(Type) | Shell and tube heat exchanger | ||||||
Water consumption (m3/h) | 5.9 | 6.8 | 8.2 | 11.3 | 13.7 | 15.3 | |
Water resistance (kPa) | 36 | 38 | 40 | 40 | 42 | 43 | |
Cooling water pipe size | DN32 | DN40 | DN50 | DN65 | |||
Cooling water pipe size | DN25 | ||||||
Refrigerant | Тype | R410A | |||||
Throttle | Capillary | ||||||
Overall dimensions | Length(mm) | 1470 | 1470 | 1470 | 1610 | 1710 | 1810 |
Width(mm) | 575 | 575 | 575 | 700 | 700 | 700 | |
Height(mm) | 2000 | 2000 | 2100 | 1850 | 1850 | 1850 | |
Weight | 210 | 280 | 360 | 450 | 700 | 820 |
Attention:
- Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉) ; The temperature of the cooling water at the inlet/outlet is 30℃(86℉)/35℃(95℉).
- We can supply equipment to customers with non-standard static pressure requirements on request.
- Electronic heater as an option.
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Specifications
Model | MF(D)-100 | MF(D)-116 | MF(D)-130 | MF(D)-153 | MF(D)-185 | MF(D)-200 | |
Cooling capacity(kW) | 100 | 116 | 130 | 153 | 185 | 200 | |
Cooling capacity(EER) | 4.39 | 4.46 | 4.39 | 4.40 | 3.85 | 3.81 | |
Cooling capacity (USRT) | 29 | 33.2 | 37.2 | 44 | 53 | 58 | |
Water consumption(m3/h) | 16500 | 19000 | 22000 | 26500 | 33000 | 36000 | |
Performance regulation | 0-25-50-75-100 | ||||||
Compressor power (kW) | 5.7×4 | 6.5×4 | 7.4×4 | 8.7×4 | 10.5×4+6.1 | 10.5×5 | |
External static pressure(Pa) | 200 | 200 | 250 | 250 | 300 | 300 | |
Electrical parameters (V/Ph/Hz) | 380~420/3/50 | ||||||
Compressor | Sealed scroll compressor | ||||||
Vaporizer | Fin & copper tube type | ||||||
Ventilator drive | Strap drive | ||||||
Condenser(Тype) | Shell and tube | ||||||
Water consumption (m3/h) | 21.2 | 24.5 | 27.5 | 32.7 | 40.2 | 43.7 | |
Water resistance (kPa) | 45 | 45 | 50 | 55 | 55 | 60 | |
Cooling water pipe size | DN65 | DN80 | |||||
Cooling water pipe size | DN25 | ||||||
Refrigerant | Type | R410A | |||||
Throttle | Thermostatic expansion valve | ||||||
Overall dimensions | Length(mm) | 2030 | 2030 | 2210 | 2210 | 2410 | 2410 |
Width(mm) | 850 | 850 | 850 | 1240 | 1460 | 1460 | |
Height(mm) | 1900 | 1900 | 1900 | 2000 | 2100 | 2100 | |
Weight(kg) | 1000 | 1100 | 1210 | 1260 | 1450 | 1480 |
Attention:
- Cooling mode: the air temperature inside the room according to the dry/wet thermometer 27℃(80.6℉)/19℃(66.2℉) ; The temperature of the cooling water at the inlet/outlet is 30℃(86℉)/35℃(95℉).
- We can supply equipment to customers with non-standard static pressure requirements on request.
- Electronic heater as an option.
- Menergy reserves the unique right to update the parameters, please refer to the sign.
Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!
Contact us today to get advice and learn more about our services!
Contacts:
Telephone: +998 (70) 202 01 32, +998 (98) 128 42 00;
Telephone: +998 (70) 202 01 32,
Email: manager.serverservice@gmail.com
We will be happy to answer your questions!
Server-Service – New level service!