Heat pumps water-water of packed type (chillers of condenser water cooling) have their outstanding features. They are used in different buildings, such as hospitals, hotels etc., but not in living quarters. That’s why these pumps are installed in industrial and public buildings.
Features of the equipment:
- Despite high indicators of efficiency, these devices of Menergy Company consume a low energy consumption.
- Long service life is provided with production technology and correct installation. Packed heat pumps have a reliable overloading protection, voltage jump and other protective system that adversely affects the equipment operation.
- Heat pumps of Menergy Company have an excellent acoustic absorption system. Therefore, the system provides a noiseless operation.
- Control of capacity if necessary.
- Each part of packed heat pump has high indicators of efficiency. These are reflux condenser, shell-and-tube heat exchanger and copper internal pipe.
- Monobloc design with compact shape allows to carry out a simple installation.
- There is also a microcomputer for intelligent control on LCD display.
- The device is equipped with a single-circle circulation system which helps to satisfy different customer’s requirements. This system also simplifies the repair and maintenance.
In order to avoid additional financial expenses, it is necessary to determine the type of heat pump capacity. There are technical parameters in the table below, with the help of which you will be able to make a right choice of the equipment you need. If you have any questions, please call our company and our specialists will give you all necessary information. Our telephone numbers: +998 (71) 207-33-32
Technical parameters
Characteristics
Model | MF(D)-28 | MF(D)-32 | MF(D)-40 | MF(D)-53 | MF(D)-64 | MF(D)-72 | |
Cooling capacity (kW) | 28 | 32 | 40 | 53 | 64 | 72 | |
Cooling capacity (EER) | 4.38 | 4.21 | 4.26 | 4.27 | 4.21 | 4.40 | |
Cooling capacity (USRT) | 8 | 10 | 11.5 | 15.2 | 18.3 | 21 | |
Air consumption (m3/h) | 4800 | 5500 | 7200 | 9500 | 11500 | 12800 | |
Capacity control | 0-50-100 | 0-25-50-75-100 | |||||
Power of compressor (kW) | 3.2×2 | 3.8×2 | 4.7×2 | 3.1×4 | 3.8×4 | 4.1×4 | |
Internal static pressure (Pa) | 80 | 100 | 100 | 120 | 150 | 200 | |
Electric parameters (V/Ph/Hz) | 380~420/3/50 | ||||||
Compressor | Sealed scroll compressor | ||||||
Evaporator | Fin & copper tube type | ||||||
Fan drive | Strap drive | ||||||
Condenser (Type) | Shell-and-tube heat exchanger | ||||||
Water consumption (m3/h) | 5.9 | 6.8 | 8.2 | 11.3 | 13.7 | 15.3 | |
Water resistance (kPa) | 36 | 38 | 40 | 40 | 42 | 43 | |
Pipe size of chilled water | DN32 | DN40 | DN50 | DN65 | |||
Pipe size of chilled water | DN25 | ||||||
Refrigerant | Type | R410A | |||||
Throttle | Capillary | ||||||
Dimension | Length (mm) | 1470 | 1470 | 1470 | 1610 | 1710 | 1810 |
Width (mm) | 575 | 575 | 575 | 700 | 700 | 700 | |
Height (mm) | 2000 | 2000 | 2100 | 1850 | 1850 | 1850 | |
Weight netto | 210 | 280 | 360 | 450 | 700 | 820 |
ATTENTION:
- Cooling mode: indoor air temperature on a dry/wet thermometer 27℃ (80.6℉)/19℃ (66.2℉); temperature of chilled water at inlet/outlet 30℃ (86℉)/35℃ (95℉).
- We can install the equipment in accordance with nonstandard requirements to static pressure on request.
- Electric heater as option.
- Menergy Company reserves the right to update the parameters
Characteristics
Model | MF(D)-100 | MF(D)-116 | MF(D)-130 | MF(D)-153 | MF(D)-185 | MF(D)-200 | |
Cooling capacity (kW) | 100 | 116 | 130 | 153 | 185 | 200 | |
Cooling capacity (EER) | 4.39 | 4.46 | 4.39 | 4.40 | 3.85 | 3.81 | |
Cooling capacity (USRT) | 29 | 33.2 | 37.2 | 44 | 53 | 58 | |
Air consumption (m3/h) | 16500 | 19000 | 22000 | 26500 | 33000 | 36000 | |
Capacity control | 0-25-50-75-100 | ||||||
Power of compressor (kW) | 5.7×4 | 6.5×4 | 7.4×4 | 8.7×4 | 10.5×4+6.1 | 10.5×5 | |
Internal static pressure (Pa) | 200 | 200 | 250 | 250 | 300 | 300 | |
Electric parameters (V/Ph/Hz) | 380~420/3/50 | ||||||
Compressor | Sealed scroll compressor | ||||||
Evaporator | Fin & copper tube type | ||||||
Fan drive | Strap drive | ||||||
Condenser (Type) | Shell and tube | ||||||
Water consumption (m3/h) | 21.2 | 24.5 | 27.5 | 32.7 | 40.2 | 43.7 | |
Water resistance (kPa) | 45 | 45 | 50 | 55 | 55 | 60 | |
Pipe size of chilled water | DN65 | DN80 | |||||
Pipe size of chilled water | DN25 | ||||||
Refrigerant | Type | R410A | |||||
Throttle | Thermostatic expansion valve | ||||||
Dimension | Length (mm) | 2030 | 2030 | 2210 | 2210 | 2410 | 2410 |
Width (mm) | 850 | 850 | 850 | 1240 | 1460 | 1460 | |
Height (mm) | 1900 | 1900 | 1900 | 2000 | 2100 | 2100 | |
Weight netto | 1100 | 1210 | 1260 | 1450 | 1480 |
ATTENTION:
- Cooling mode: indoor air temperature on a dry/wet thermometer 27℃ (80.6℉)/19℃ (66.2℉); temperature of chilled water at inlet/outlet 30℃ (86℉)/35℃ (95℉).
- We can install the equipment in accordance with nonstandard requirements to static pressure on request.
- Electric heater as option.
- Menergy Company reserves the right to update the parameters