Water-cooled monoblock heat pump ceiling type (monoblock water-to-air heat pump)

Моноблочный тепловой насос в Ташкенте Узбекистане

Monoblock heat pumps Menergy are intended for heating or cooling a building.

According to the type of work, they belong to the category “water-air”. A pump is used to convert the heat of groundwater into warm air.

The equipment is characterized by a wide range of applications. It is installed in residential premises, industrial enterprises, and administrative buildings.

Equipment features:

  • Large diameter tubular heat exchanger ensures good heat exchange, stable operation and reliable protection from low temperatures.
  • Refrigerants are used R410A, R407C и R22.
  • Silent operation (up to 50 dB) thanks to the use of sound-absorbing materials.
  • The stable wear technology increases the durability of the split system.
  • Easy to operate, adjustable to required values.
  • Availability of a microcomputer for control.
  • Remote control capability.

Important!

Choosing a water monoblock heat pump is a responsible task. Contact our specialists who are always ready to help you with your choice.

You can find detailed information about our company in the section “Contacts”

Technical parameters

Water loop – Water Loop

Model 2600 3500 4500 5800 7200 8600 10500 12600 14600 17500/S
Nom. cooling capacity (KW) 2.6 3.5 4.5 5.8 7.2 8.6 10.5 12.6 14.6 17.5
EER 4.41 4.27 4.41 4.30 4.36 4.43 4.18 4.17 4.21 4.19
Nom. heating capacity (KW) 3.00 3.95 5.10 6.48 8.10 9.40 11.40 13.60 15.80 19.6
COP 4.76 4.65 4.64 4.47 4.66 4.63 4.21 4.20 4.27 4.45
Cooling capacity(USRT) 0.74 1.00 1.29 1.66 2.06 2.46 3.00 3.60 4.17 5
Thermal performance(USRT) 0.83 1.13 1.46 1.93 2.32 2.75 3.36 4.07 4.75 5.6
Air flow (m3/h) 520 715 910 1190 1480 1760 2150 2570 3010 3600
External static pressure (Pa) 12(8) 20(12) 30(20) 50(30) 80(50)
Input power in cooling (KW) 0.59 0.82 1.02 1.35 1.65 1.94 2.51 3.02 3.47 4.18
Input power in heating (KW) 0.63 0.85 1.10 1.45 1.74 2.03 2.71 3.24 3.70 4.40
Electrical parameters (V/Ph/Hz) 230/1/50 380~420/3/50
Input current in cooling (A) 2.7 3.9 4.9 6.5 7.8 9.3 11.6 14 16 6.54
Input current in heating (A) 3.0 4.0 5.2 6.9 8.2 9.7 12.6 15.0 17.1 7.0
Compressor type/quantity Rotary/1 Rotary/2 Spiral/1
Noise level dB (A) 38.5 38.5 40 40 41 42.5 43.5 43.5 45 50
Overall dimensions Length 1050 1050 1050 1050 1100 1100 1300 1300 1400 1700
Width 500 500 500 500 560 560 680 680 680 680
Height 360 360 420 420 485 485 525 525 525 550
Weight(kg) 60 65 75 85 100 110 130 150 160 240
Water consumption (m3/h) 0.58 0.72 0.92 1.25 1.52 1.85 2.25 2.66 3.12 3.65
Coolant View R410a
Volume(kg) 0.6 0.8 1.1 1.3 1.45 1.5 2×0.9 2×0.95 2×1.25 2.1
Water pipe at the inlet and outlet (diameter) R3/4(DN20) R1(DN25) R1-1/4(DN32)
Condensate pipe (diameter) R3/4(DN20) R1(DN25)

Attention:

  1. In cooling mode: air temperature 27 ℃/19℃(dry/wet bulb); water temperature 30℃/35℃ (input/output).
  2. In heating mode: air temperature 20℃/15 ℃ (dry/wet bulb) ; water temperature 20 ℃ at the inlet.
  3. Equipment with cooling only function does not have parameters in heating mode.
  4. Menergy reserves the right to update parameters.

Underground groundwater – Ground Water

Model 2600 3500 4500 5800 7200 8600 10500 12600 14600 17500/S  
Nom. cooling capacity (KW) 2.6 3.5 4.5 5.8 7.2 8.6 10.5 12.6 14.6 17.5
EER 4.73 4.43 4.09 4.46 4.44 4.57 4.47 4.41 4.46 4.32
Nom. heating capacity (KW) 2.80 3.70 4.50 5.70 7.30 8.70 10.40 12.60 14.50 17.3
COP 4.59 4.51 4.09 4.29 4.17 4.46 4.19 4.17 4.13 4.02
Cooling capacity(USRT) 0.74 1.00 1.29 1.66 2.06 2.46 3.00 3.60 4.17 5
Thermal performance(USRT) 0.80 1.06 1.35 1.71 2.12 2.46 3.00 3.60 4.17 5
Air flow (m3/h) 520 715 910 1190 1480 1760 2150 2570 3010 3600
External static pressure (Pa) 12(8) 20(12)     30(20)   50(30)     80(50)
Input power in cooling (KW) 0.55 0.79 1.10 1.3 1.62 1.88 2.35 2.86 3.27 4.05
Input power in heating (KW) 0.61 0.82 1.10 1.33 1.75 1.95 2.48 3.02 3.51 4.30
Electrical parameters (V/Ph/Hz) 230/1/50 380~420/3/50
Input current in cooling (A) 2.7 3.8 5.1 6.3 7.8 8.6 10.7 13 14.87 6.4
Input current in heating (A) 2.90 3.90 5.10 6.40 8.40 8.40 11.30 13.80 15.96 6.80
Compressor type/quantity Rotary/1 Rotary/2 Scroll/1
Noise level dB (A) 38.5 38.5 40 40 41 42.5 43.5 43.5 45 50
Overall dimensions (mm) Length 1050 1050 1050 1050 1100 1100 1300 1300 1400 1700
Width 500 500 500 500 560 560 680 680 680 680
Height 360 360 420 420 485 485 525 525 525 550
Weight (kg) 60 65 75 85 100 110 130 150 160 240
Water consumption (m3/h) 0.26 0.35 0.44 0.6 0.73 0.88 1.08 1.27 1.52  
Coolant View R410a
Volume(kg) 0.6 0.8 0.95 1.1 1.25 1.5 2×0.9 2×0.95 2×1.25 2.1
Water pipe at the inlet and outlet (diameter) R3/4(DN20) R1(DN25) R1-1/4(DN32)
Condensate pipe (diameter) R3/4(DN20) R1(DN25)

Attention:

  1. In cooling mode: air temperature 27 ℃/19℃ (dry/wet bulb); water temperature 18 ℃/29 ℃(inlet/outlet).
  2. In heating mode: air temperature 20 ℃/15 ℃(dry/wet bulb); water temperature 20 ℃ at the inlet.
  3. Equipment with cooling only function does not have parameters in heating mode
  4. Menergy reserves the right to update parameters.

Geothermal loop – Underground Loop

Model 2600 3500 4500 5800 7200 8600 10500 12600 14600 17500/S  
Nom. cooling capacity (KW) 2.6 3.5 4.5 5.8 7.2 8.6 10.5 12.6 14.6 17.5
EER 4.33 4.49 4.25 4.17 4.19 4.28 4.38 4.32 4.42 4.27
Nom. heating capacity (KW) 2.48 3.20 4.10 5.30 6.60 7.90 9.60 11.50 13.50 16.2
COP 4.43 4.21 4.06 4.21 4.15 4.34 4.25 4.14 4.27 4.00
Cooling capacity(USRT) 0.74 1.00 1.29 1.66 2.06 2.46 3.00 3.60 4.17 5
Thermal performance(USRT) 0.71 0.91 1.23 1.57 1.94 2.31 2.86 3.37 3.86 4.51
Air flow (m3/h) 520 715 910 1190 1480 1760 2150 2570 3010 3600
External static pressure (Pa) 12(8) 20(12) 30(20) 50(30) 80(50)
Input power in cooling (KW) 0.6 0.78 1.06 1.39 1.72 2.01 2.4 2.92 3.3 4.1
Input power in heating (KW) 0.56 0.76 1.01 1.26 1.59 1.82 2.26 2.78 3.16 4.05
Electrical parameters (V/Ph/Hz) 230/1/50 380~420/3/50
Input current in cooling (A) 2.9 3.7 5.1 6.6 8.2 9.2 10.9 13 14.9 6.6
Input current in heating (A) 2.80 3.60 4.80 6.00 7.60 8.30 10.30 12.65 14.40 6.40
Compressor type/quantity Rotary/1 Rotary/2   Spiral/1
Noise level dB (A) 38.5 38.5 40 40 41 42.5 43.5 43.5 45 50
Overall dimensions (mm) Length 1050 1050 1050 1050 1100 1100 1300 1300 1400 1700
Width 500 500 500 500 560 560 680 680 680 680
Height 360 360 420 420 485 485 525 525 525 550
Weight (kg) 60 65 75 85 100 110 130 150 160 240
Water consumption (m3/h) 0.59 0.75 0.9 1.24 1.5 1.85 2.25 2.6 3.12 3.6
Coolant View R410a
Volume(kg) 0.6 0.8 0.95 1.1 1.25 1.5 2×0.9 2×0.95 2×1.25 2.1
Water pipe at the inlet and outlet (diameter) R3/4(DN20) R1(DN25) R1-1/4(DN32)
Condensate pipe (diameter) R3/4(DN20) R1(DN25)

Attention!

  1. In cooling mode: air temperature 27℃/19℃(dry/wet bulb); water temperature 25℃/30℃(inlet/outlet).
  2. In heating mode: air temperature 20 ℃/15 ℃(dry/wet bulb); water temperature 12 ℃ at the inlet.
  3. Equipment with cooling only function does not have parameters in heating mode
  4. Menergy reserves the right to update parameters.

Server-Service is your reliable partner in creating a comfortable climate in your home, office or enterprise!

Contact us today to get advice and learn more about our services!

Contacts:

Telephone: +998 (70) 202 01 32, 

                     +998 (98) 128 42 00;

Email: manager.serverservice@gmail.com

We will be happy to answer your questions!

Server-Service – New level service!