Description
| Specification | SKS-50 | ||
| Steam capacity | kg/h | 50 | |
| Max. working pressure | mPa/bar | 0.7 mPa / 7 bar | |
| Power | kW | 40 | |
| kcal/h | 32.040 | ||
| Efficiency | % | more 86% | |
| Heated area | m2 | 2.6 | |
| Quantity of water in boiler | l | 40 | |
| Weight | kg | 305 | |
| Voltage | V | 220 V | |
| Electrical capacity | General current consumption | kW | 0,3 |
| Motor of burner | kW | 0,04 | |
| Feed water pump | kW | 0,25 | |
| Dimension | Width | mm | 530 |
| Length | mm | 530 | |
| Height | mm | 1150 | |
| Method of combustion | artificial ventilation | ||
| Control system | on/off | ||
| Fuel consumption | Diesel | kg/h | 3,61 |
| Kerosine | kg/h | 3,59 | |
| Gas | m3/h | 3,76 | |
| Connecting pipes diameter | pipe of steam outflow | mm | 20 |
| water inlet pipe | mm | 15 | |
| drain pipe | mm | 20 | |
| pipe for cleaning | mm | 32 | |
| Coaxial chimney | mm | 120 | |